Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,116
matching recommendationsSIC | 281 | Industrial Inorganic Chemicals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0537 # 02 Y:2016 | 02 | 2016 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $21,873 | $21,829 | Not Implemented |
SD0537 # 03 Y:2016 | 03 | 2016 | OPTIMIZE PLANT POWER FACTOR | $10,293 | $10,000 | Not Implemented |
SD0537 # 04 Y:2016 | 04 | 2016 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $9,320 | $22,960 | Not Implemented |
SD0537 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,406 | $10,314 | Implemented |
SD0537 # 06 Y:2016 | 06 | 2016 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,089 | $7,880 | Not Implemented |
SD0537 # 07 Y:2016 | 07 | 2016 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,758 | $5,550 | Not Implemented |
SD0537 # 08 Y:2016 | 08 | 2016 | USE PHOTOCELL CONTROLS | $1,432 | $4,070 | Not Implemented |
SD0537 # 09 Y:2016 | 09 | 2016 | INSTALL OCCUPANCY SENSORS | $1,312 | $3,610 | Implemented |
SD0537 # 10 Y:2016 | 10 | 2016 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,205 | $2,550 | Not Implemented |
UM0471 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,290 | $500 | n/a |
UM0471 # 02 Y:2016 | 02 | 2016 | INSTALL OCCUPANCY SENSORS | $1,462 | $1,750 | n/a |
UM0471 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $696 | $2,500 | n/a |
UM0471 # 04 Y:2016 | 04 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,519 | $5,500 | n/a |
UM0471 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,664 | $3,435 | n/a |
DL0164 # 01 Y:2016 | 01 | 2016 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $109,877 | $5,990 | Not Implemented |
DL0164 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,095 | $32,300 | Not Implemented |
DL0164 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,513 | $59,950 | Implemented |
DL0164 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,804 | $11,335 | Not Implemented |
DL0164 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,606 | $16,930 | Not Implemented |
DL0164 # 06 Y:2016 | 06 | 2016 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $319,299 | $522,826 | Not Implemented |
TT0169 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,315 | $4,500 | Implemented |
TT0169 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,575 | $3,500 | Implemented |
TT0169 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $3,461 | $3,240 | Implemented |
TT0169 # 04 Y:2016 | 04 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $2,943 | $1,500 | Implemented |
TT0169 # 05 Y:2016 | 05 | 2016 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $1,333 | $2,275 | Not Implemented |