Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
83
matching recommendationsSIC | 2819 | Industrial Inorganic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0743 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,000 | $1,800 | Implemented |
UD0743 # 14 Y:2006 | 14 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,158 | $15,600 | Not Implemented |
UD0743 # 16 Y:2006 | 16 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,181 | $12,130 | Not Implemented |
UD0743 # 17 Y:2006 | 17 | 2006 | USE PHOTOCELL CONTROLS | $2,428 | $1,776 | Not Implemented |
UD0743 # 18 Y:2006 | 18 | 2006 | USE PHOTOCELL CONTROLS | $2,147 | $0 | Not Implemented |
UD0743 # 19 Y:2006 | 19 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,710 | $0 | Not Implemented |
UD0743 # 20 Y:2006 | 20 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,342 | $500 | Implemented |
UD0743 # 21 Y:2006 | 21 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $831 | $0 | Implemented |
UD0743 # 13 Y:2006 | 13 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $8,946 | $0 | Not Implemented |
UD0743 # 12 Y:2006 | 12 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,125 | $12,000 | Not Implemented |
UD0743 # 11 Y:2006 | 11 | 2006 | USE OPTIMUM TEMPERATURE | $13,681 | $0 | Not Implemented |
UD0743 # 10 Y:2006 | 10 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $15,000 | $0 | Implemented |
UD0743 # 09 Y:2006 | 09 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $17,000 | $0 | Implemented |
UD0704 # 03 Y:2004 | 03 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $846 | $900 | Implemented |
UD0704 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $3,335 | $6,000 | Not Implemented |
UD0704 # 01 Y:2004 | 01 | 2004 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $10,368 | $0 | Implemented |
UD0704 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $652 | $300 | Not Implemented |
UD0704 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $668 | $700 | Implemented |
UD0704 # 06 Y:2004 | 06 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $0 | Implemented |
UD0704 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $223 | $500 | Implemented |
UD0241 # 09 Y:1988 | 09 | 1988 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $9,932 | $22,000 | Not Implemented |
UD0241 # 08 Y:1988 | 08 | 1988 | INSULATE BARE EQUIPMENT | $1,546 | $2,200 | Not Implemented |
UD0241 # 07 Y:1988 | 07 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,040 | $15,000 | Not Implemented |
UD0241 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,574 | $1,000 | Implemented |
UD0241 # 05 Y:1988 | 05 | 1988 | OPERATE BOILERS ON HIGH FIRE SETTING | $7,000 | $5,000 | Not Implemented |