Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 2819 | Industrial Inorganic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0537 # 07 Y:2016 | 07 | 2016 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,758 | $5,550 | Not Implemented |
SD0537 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,406 | $10,314 | Implemented |
SD0537 # 04 Y:2016 | 04 | 2016 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $9,320 | $22,960 | Not Implemented |
SD0537 # 08 Y:2016 | 08 | 2016 | USE PHOTOCELL CONTROLS | $1,432 | $4,070 | Not Implemented |
SD0537 # 06 Y:2016 | 06 | 2016 | REDUCE HEAT GAIN BY WINDOW TINTING | $2,089 | $7,880 | Not Implemented |
SD0537 # 02 Y:2016 | 02 | 2016 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $21,873 | $21,829 | Not Implemented |
SD0537 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $23,109 | $108,180 | Not Implemented |
SD0537 # 10 Y:2016 | 10 | 2016 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,205 | $2,550 | Not Implemented |
SD0537 # 09 Y:2016 | 09 | 2016 | INSTALL OCCUPANCY SENSORS | $1,312 | $3,610 | Implemented |
SD0537 # 03 Y:2016 | 03 | 2016 | OPTIMIZE PLANT POWER FACTOR | $10,293 | $10,000 | Not Implemented |
SF0248 # 05 Y:2002 | 05 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $513 | $700 | Not Implemented |
SF0248 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,409 | $13,000 | Implemented |
SF0248 # 04 Y:2002 | 04 | 2002 | USE PHOTOCELL CONTROLS | $5,341 | $6,000 | Implemented |
SF0248 # 03 Y:2002 | 03 | 2002 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,713 | $1,685 | Implemented |
SF0248 # 02 Y:2002 | 02 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,169 | $1,436 | Not Implemented |
SF0248 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,662 | $0 | Implemented |
SF0248 # 07 Y:2002 | 07 | 2002 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $840 | $0 | Not Implemented |
SD0219 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,370 | $68,000 | Implemented |
SD0219 # 02 Y:1999 | 02 | 1999 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,464 | $3,500 | Not Implemented |
SD0219 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $412 | $144 | Implemented |
SD0219 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,142 | $2,500 | Not Implemented |
SD0219 # 05 Y:1999 | 05 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,981 | $9,500 | Not Implemented |
SD0219 # 06 Y:1999 | 06 | 1999 | CONVERT TO AQUEOUS CLEANING | $11,000 | $0 | Implemented |
SD0219 # 07 Y:1999 | 07 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,400 | $2,000 | Implemented |
SD0219 # 08 Y:1999 | 08 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $11,118 | $2,000 | Implemented |