Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsSIC | 2819 | Industrial Inorganic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0112 # 02 Y:2006 | 02 | 2006 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $57,168 | $11,016 | Implemented |
IC0112 # 01 Y:2006 | 01 | 2006 | REPLACE BOILER | $300,562 | $414,240 | Not Implemented |
IC0112 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,114 | $0 | Implemented |
IC0112 # 06 Y:2006 | 06 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $48,787 | $157,465 | Implemented |
IC0112 # 05 Y:2006 | 05 | 2006 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $28,585 | $165,480 | Not Implemented |
IC0112 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,753 | $2,300 | Implemented |
IC0112 # 03 Y:2006 | 03 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $44,296 | $145,126 | Implemented |
IC0112 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $42,495 | $66,129 | Not Implemented |
IC0111 # 07 Y:2006 | 07 | 2006 | USE MINIMUM STEAM OPERATING PRESSURE | $22,776 | $0 | Implemented |
IC0111 # 12 Y:2006 | 12 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $45,671 | $195,432 | Implemented |
IC0111 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,163 | $1,600 | Implemented |
IC0111 # 10 Y:2006 | 10 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,406 | $19,704 | Implemented |
IC0111 # 09 Y:2006 | 09 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $158,427 | $5,152 | Implemented |
IC0111 # 03 Y:2006 | 03 | 2006 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $186,788 | $135,156 | Not Implemented |
IC0111 # 05 Y:2006 | 05 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,047 | $30,000 | Not Implemented |
IC0111 # 06 Y:2006 | 06 | 2006 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $57,000 | $36,000 | Not Implemented |
IC0111 # 08 Y:2006 | 08 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $9,304 | $2,800 | Implemented |
IC0111 # 02 Y:2006 | 02 | 2006 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $95,000 | $442,680 | Not Implemented |
IC0111 # 04 Y:2006 | 04 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $93,000 | $235,998 | Implemented |
IC0111 # 01 Y:2006 | 01 | 2006 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $803,012 | $258,000 | Implemented |
IC0103 # 07 Y:2005 | 07 | 2005 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $330 | $2,800 | Not Implemented |
IC0103 # 01 Y:2005 | 01 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $12,792 | $12,792 | Not Implemented |
IC0103 # 02 Y:2005 | 02 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $8,631 | $4,680 | Not Implemented |
IC0103 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $2,344 | $1,400 | Not Implemented |
IC0103 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,340 | $300 | Not Implemented |