Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 283 | Drugs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0224 # 11 Y:2001 | 11 | 2001 | INSTALL OCCUPANCY SENSORS | $17,495 | $33,556 | n/a |
SF0224 # 10 Y:2001 | 10 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $259,156 | $256,500 | n/a |
SF0224 # 09 Y:2001 | 09 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,142 | $6,113 | n/a |
SF0224 # 08 Y:2001 | 08 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $11,660 | $9,500 | n/a |
SF0224 # 07 Y:2001 | 07 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,962 | $13,200 | n/a |
SF0224 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,146 | $2,800 | n/a |
SF0224 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $10,562 | $3,240 | n/a |
SF0224 # 04 Y:2001 | 04 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $18,526 | $4,994 | n/a |
SF0224 # 03 Y:2001 | 03 | 2001 | CLOSE OFF UNNEEDED STEAM LINES | $2,618 | $172 | n/a |
SF0224 # 02 Y:2001 | 02 | 2001 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,556 | $0 | n/a |
SF0224 # 01 Y:2001 | 01 | 2001 | INSTALL OCCUPANCY SENSORS | $9,345 | $540 | n/a |
SF0224 # 12 Y:2001 | 12 | 2001 | OPTIMIZE PLANT POWER FACTOR | $120,158 | $160,000 | n/a |
UM0190 # 04 Y:2001 | 04 | 2001 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $293,000 | $360,000 | Not Implemented |
UM0190 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,684 | $1,000 | Not Implemented |
UM0190 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $20,286 | $8,250 | Implemented |
UM0190 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $81,576 | $80,632 | Implemented |
UM0190 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $20,468 | $9,600 | Not Implemented |
UM0190 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $82,700 | $8,000 | Not Implemented |
OK0617 # 01 Y:2001 | 01 | 2001 | INSTALL OCCUPANCY SENSORS | $335 | $304 | Implemented |
OK0617 # 07 Y:2001 | 07 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $23,985 | $27,632 | Not Implemented |
OK0617 # 06 Y:2001 | 06 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $1,170 | $1,000 | Not Implemented |
OK0617 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,337 | $9,259 | Not Implemented |
OK0617 # 04 Y:2001 | 04 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $409 | $354 | Not Implemented |
OK0617 # 03 Y:2001 | 03 | 2001 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $17,946 | $30,145 | Not Implemented |
OK0617 # 02 Y:2001 | 02 | 2001 | INSTALL SET-BACK TIMERS | $323 | $439 | Implemented |