Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

54

matching recommendations
Reset
SIC 284 Soap, Cleaners, And Toilet Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0736 # 12 Y:2006 12 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,612 $26,000 Implemented
UD0736 # 09 Y:2006 09 2006 REPAIR OR REPLACE STEAM TRAPS $11,892 $240 Implemented
UD0736 # 08 Y:2006 08 2006 INSULATE FEEDWATER TANK $12,187 $6,825 Implemented
UD0736 # 06 Y:2006 06 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $29,264 $40,000 Implemented
UD0736 # 05 Y:2006 05 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32,384 $28,000 Implemented
UD0736 # 03 Y:2006 03 2006 REPAIR AND ELIMINATE STEAM LEAKS $36,074 $28,000 Implemented
UD0736 # 02 Y:2006 02 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $151,099 $230,000 Implemented
WV0224 # 06 Y:2001 06 2001 INSULATE BARE EQUIPMENT $1,103 $120 Implemented
WV0224 # 11 Y:2001 11 2001 RECOVER AND REUSE COOLING WATER $25,740 $89,000 Implemented
WV0224 # 01 Y:2001 01 2001 INCREASE AMOUNT OF CONDENSATE RETURNED $34,989 $13,233 Implemented
WV0224 # 04 Y:2001 04 2001 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,489 $2,436 Implemented
WV0224 # 05 Y:2001 05 2001 INSULATE BARE EQUIPMENT $1,215 $583 Implemented
WV0224 # 08 Y:2001 08 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,361 $2,160 Implemented
WV0224 # 07 Y:2001 07 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $13,668 $2,160 Implemented
UD0598 # 09 Y:2000 09 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,088 $4,253 Implemented
UD0598 # 08 Y:2000 08 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,720 $500 Implemented
UD0598 # 06 Y:2000 06 2000 USE MINIMUM STEAM OPERATING PRESSURE $3,333 $0 Implemented
UD0598 # 05 Y:2000 05 2000 CHECK FOR ACCURACY OF UTILITY / POWER METERS $9,640 $0 Implemented
UD0598 # 02 Y:2000 02 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $22,073 $34,288 Implemented
UD0481 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $816 $240 Implemented
UD0207 # 03 Y:1986 03 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $295 $240 Implemented
UD0207 # 02 Y:1986 02 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,860 $485 Implemented
UD0171 # 02 Y:1985 02 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,014 $17,000 Implemented
UD0171 # 01 Y:1985 01 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,352 $4,773 Implemented
UD0030 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,014 $0 Implemented