Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
84
matching recommendationsSIC | 2851 | Paints And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0851 # 11 Y:2012 | 11 | 2012 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $69,895 | $32,000 | Not Implemented |
UD0851 # 12 Y:2012 | 12 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $27,723 | $31,000 | Not Implemented |
UD0851 # 13 Y:2012 | 13 | 2012 | REDUCE EXCESSIVE BOILER BLOWDOWN | $5,863 | $5,000 | Not Implemented |
UD0851 # 14 Y:2012 | 14 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,300 | $1,000 | Not Implemented |
UD0851 # 15 Y:2012 | 15 | 2012 | REDUCE VENTILATION AIR | $10,721 | $32,160 | Not Implemented |
WV0276 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $8,969 | $500 | Not Implemented |
WV0276 # 03 Y:2003 | 03 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $30,964 | $9,195 | Not Implemented |
WV0276 # 02 Y:2003 | 02 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $33,509 | $580 | Implemented |
WV0276 # 01 Y:2003 | 01 | 2003 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $41,760 | $60,000 | Implemented |
WV0276 # 05 Y:2003 | 05 | 2003 | USE OPTIMUM THICKNESS INSULATION | $8,395 | $2,640 | Implemented |
WV0276 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,737 | $16,926 | Implemented |
WV0276 # 07 Y:2003 | 07 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $2,328 | $480 | Implemented |
WV0276 # 08 Y:2003 | 08 | 2003 | INSTALL OCCUPANCY SENSORS | $2,514 | $2,200 | Implemented |
WV0276 # 09 Y:2003 | 09 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,770 | $80 | Implemented |
WV0276 # 10 Y:2003 | 10 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,195 | $0 | Not Implemented |
WV0276 # 11 Y:2003 | 11 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $744 | $320 | Implemented |
UM0188 # 02 Y:2001 | 02 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,080 | $500 | Not Implemented |
UM0188 # 04 Y:2001 | 04 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $263 | $1,020 | Not Implemented |
UM0188 # 03 Y:2001 | 03 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,400 | $2,800 | Not Implemented |
UM0188 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,363 | $1,083 | Not Implemented |
UM0188 # 05 Y:2001 | 05 | 2001 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $3,333 | $1,500 | Implemented |
UD0111 # 03 Y:1983 | 03 | 1983 | INSTALL STORM WINDOWS AND DOORS | $4,375 | $2,890 | Implemented |
UD0111 # 01 Y:1983 | 01 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $992 | $600 | Implemented |
UD0111 # 02 Y:1983 | 02 | 1983 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $27,776 | $2,095 | Not Implemented |
UD0111 # 04 Y:1983 | 04 | 1983 | INSTALL STORM WINDOWS AND DOORS | $928 | $1,200 | Implemented |