Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 2851 | Paints And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0709 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $696 | $4,181 | Not Implemented |
OK0709 # 01 Y:2005 | 01 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $2,560 | $0 | Not Implemented |
OK0709 # 02 Y:2005 | 02 | 2005 | INSULATE BARE EQUIPMENT | $3,684 | $1,030 | Implemented |
OK0709 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,659 | $11,363 | Not Implemented |
OK0709 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,493 | $21,700 | Not Implemented |
OK0709 # 05 Y:2005 | 05 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,000 | $0 | Not Implemented |
OK0709 # 06 Y:2005 | 06 | 2005 | INSTALL SET-BACK TIMERS | $4,055 | $2,205 | Not Implemented |
OK0709 # 07 Y:2005 | 07 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,077 | $4,640 | Not Implemented |
OK0709 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $541 | $3,034 | Not Implemented |
OK0709 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $824 | $1,820 | Not Implemented |
OK0709 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $127 | $109 | Not Implemented |
OK0709 # 11 Y:2005 | 11 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $159 | $1,000 | Not Implemented |
OK0613 # 02 Y:2001 | 02 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,071 | $4,000 | Implemented |
OK0613 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $304 | $125 | Not Implemented |
OK0613 # 07 Y:2001 | 07 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,400 | $572 | Not Implemented |
OK0613 # 06 Y:2001 | 06 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $54,883 | $20,680 | Not Implemented |
OK0613 # 05 Y:2001 | 05 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,508 | $6,000 | Not Implemented |
OK0613 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,475 | $7,120 | Not Implemented |
OK0613 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $456 | $2,600 | Implemented |
OK0613 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $10,756 | $1,026 | Not Implemented |
OK0558 # 05 Y:1998 | 05 | 1998 | COVER INK CONTAINERS WHEN NOT IN USE | $49,090 | $5,700 | Implemented |
OK0558 # 04 Y:1998 | 04 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $149,760 | $280,000 | Implemented |
OK0558 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $4,561 | $3,300 | Not Implemented |
OK0558 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,594 | $0 | Implemented |
OK0558 # 01 Y:1998 | 01 | 1998 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $43,625 | $44,730 | Not Implemented |