Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 286 | Industrial Organic Chemicals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0143 # 04 Y:2015 | 04 | 2015 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,988 | $0 | Not Implemented |
DL0143 # 07 Y:2015 | 07 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $855 | $0 | Implemented |
DL0143 # 06 Y:2015 | 06 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $1,582 | $3,000 | Implemented |
DL0143 # 05 Y:2015 | 05 | 2015 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,468 | $200 | Not Implemented |
DL0143 # 03 Y:2015 | 03 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,030 | $1,000 | Not Implemented |
DL0143 # 02 Y:2015 | 02 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,928 | $0 | Implemented |
DL0143 # 01 Y:2015 | 01 | 2015 | REDUCE VENTILATION AIR | $12,970 | $0 | Implemented |
WV0450 # 07 Y:2012 | 07 | 2012 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $11,389 | $6,500 | Implemented |
WV0450 # 13 Y:2012 | 13 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,764 | $1,800 | Not Implemented |
WV0450 # 12 Y:2012 | 12 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,314 | $3,360 | Not Implemented |
WV0450 # 11 Y:2012 | 11 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $8,489 | $1,210 | Implemented |
WV0450 # 10 Y:2012 | 10 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,953 | $18,267 | Implemented |
WV0450 # 09 Y:2012 | 09 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,686 | $21,120 | Not Implemented |
WV0450 # 08 Y:2012 | 08 | 2012 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $10,199 | $1,000 | Not Implemented |
WV0450 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $36,667 | $21,800 | Not Implemented |
WV0450 # 05 Y:2012 | 05 | 2012 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $97,121 | $400,000 | Not Implemented |
WV0450 # 04 Y:2012 | 04 | 2012 | REDESIGN PROCESS | $102,043 | $230,000 | Not Implemented |
WV0450 # 03 Y:2012 | 03 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $130,899 | $157,320 | Implemented |
WV0450 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $141,590 | $210,000 | Not Implemented |
WV0450 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $173,557 | $1,000 | Implemented |
WV0382 # 15 Y:2008 | 15 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $766 | $3,539 | Implemented |
WV0382 # 02 Y:2008 | 02 | 2008 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $109,212 | $38,900 | Implemented |
WV0382 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,966 | $8,615 | Not Implemented |
WV0382 # 04 Y:2008 | 04 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,388 | $8,615 | Not Implemented |
WV0382 # 05 Y:2008 | 05 | 2008 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $11,112 | $100,800 | Not Implemented |