Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
135
matching recommendationsSIC | 2865 | Cyclic Crudes And Intermediates |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0276 # 08 Y:2001 | 08 | 2001 | INSTALL STEAM TRAP | $14,111 | $1,200 | Implemented |
UF0276 # 09 Y:2001 | 09 | 2001 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $21,330 | $45,000 | Implemented |
AM0402 # 01 Y:2001 | 01 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $632,000 | $1,210 | Implemented |
AM0402 # 02 Y:2001 | 02 | 2001 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $248,500 | $1,730,000 | Not Implemented |
AM0402 # 03 Y:2001 | 03 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $61,175 | $15,000 | n/a |
AM0402 # 04 Y:2001 | 04 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $27,400 | $1,000 | Implemented |
AM0402 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,070 | $53,700 | n/a |
AM0402 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $19,300 | $865 | Implemented |
AM0402 # 07 Y:2001 | 07 | 2001 | USE SYNTHETIC LUBRICANT | $11,100 | $0 | Not Implemented |
AM0402 # 08 Y:2001 | 08 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,700 | $3,300 | Not Implemented |
AM0402 # 09 Y:2001 | 09 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,200 | $0 | Implemented |
AM0402 # 10 Y:2001 | 10 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,325 | $0 | Implemented |
AM0402 # 11 Y:2001 | 11 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,010 | $0 | Implemented |
UL0172 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $195 | $500 | Not Implemented |
UL0172 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $990 | $3,186 | Not Implemented |
UL0172 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $600 | $9,340 | Implemented |
UL0172 # 04 Y:1996 | 04 | 1996 | IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL | $199,480 | $26,580 | Not Implemented |
UL0172 # 05 Y:1996 | 05 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $16,140 | $9,500 | Not Implemented |
UL0172 # 06 Y:1996 | 06 | 1996 | WASH AND REUSE RAGS ON-SITE | $1,860 | $4,500 | Not Implemented |
UL0172 # 07 Y:1996 | 07 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $22,850 | $0 | Not Implemented |
UL0172 # 08 Y:1996 | 08 | 1996 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $12,180 | $0 | Not Implemented |
RU0132 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $952 | $0 | Not Implemented |
RU0132 # 02 Y:1991 | 02 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,283 | $0 | Not Implemented |
RU0132 # 03 Y:1991 | 03 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $7,363 | $5,000 | Not Implemented |
RU0132 # 04 Y:1991 | 04 | 1991 | IMPROVE LUBRICATION PRACTICES | $3,958 | $0 | Not Implemented |