Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

52

matching recommendations
Reset
SIC 289 Miscellaneous Chemical Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1613 # 03 Y:2017 03 2017 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,962 $4,550 Not Implemented
UK1613 # 04 Y:2017 04 2017 PREHEAT COMBUSTION AIR WITH WASTE HEAT $3,332 $4,602 Not Implemented
UK1613 # 05 Y:2017 05 2017 INSTALL OCCUPANCY SENSORS $3,544 $1,386 Not Implemented
UK1613 # 06 Y:2017 06 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,264 $1,200 Implemented
UK1613 # 07 Y:2017 07 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $871 $0 Implemented
UK1613 # 08 Y:2017 08 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $535 $0 Implemented
UK1613 # 10 Y:2017 10 2017 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $145 $0 Implemented
UD0643 # 02 Y:2002 02 2002 REPLACE BOILER $24,688 $93,993 Not Implemented
UD0643 # 03 Y:2002 03 2002 BURN A LESS EXPENSIVE GRADE OF FUEL $18,168 $0 Not Implemented
UD0643 # 04 Y:2002 04 2002 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $11,525 $0 Not Implemented
UD0643 # 05 Y:2002 05 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,904 $25,000 n/a
UD0643 # 06 Y:2002 06 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,223 $268 Not Implemented
UD0643 # 07 Y:2002 07 2002 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $4,989 $11,500 n/a
UD0643 # 08 Y:2002 08 2002 INSTALL TIMERS AND/OR THERMOSTATS $4,481 $1,000 Not Implemented
UD0643 # 09 Y:2002 09 2002 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,882 $1,000 Not Implemented
UD0643 # 10 Y:2002 10 2002 USE PHOTOCELL CONTROLS $1,370 $825 Not Implemented
UD0643 # 01 Y:2002 01 2002 BURN A LESS EXPENSIVE GRADE OF FUEL $32,894 $90,000 n/a
UD0643 # 11 Y:2002 11 2002 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $254 $300 Not Implemented
TN0525 # 08 Y:1994 08 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $271 $915 Not Implemented
TN0525 # 07 Y:1994 07 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,548 $510 Implemented
TN0525 # 06 Y:1994 06 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,613 $0 Not Implemented
TN0525 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,625 $0 Implemented
TN0525 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,076 $480 Implemented
TN0525 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,540 $1,786 Implemented
TN0525 # 02 Y:1994 02 1994 INSTALL TIMERS AND/OR THERMOSTATS $6,276 $585 Implemented