Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

735

matching recommendations
Reset
SIC 2899 Chemical Preparations, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0346 # 09 Y:2006 09 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $534 $131 Not Implemented
OK0727 # 01 Y:2006 01 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,431 $2,462 Implemented
OK0727 # 02 Y:2006 02 2006 INSTALL TIMERS AND/OR THERMOSTATS $1,646 $75 Implemented
OK0727 # 03 Y:2006 03 2006 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $12,463 $40,452 Not Implemented
OK0727 # 04 Y:2006 04 2006 USE GRAVITY FEEDS WHEREVER POSSIBLE $10,056 $1,636 Not Implemented
OK0727 # 05 Y:2006 05 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,960 $8,407 Not Implemented
OK0727 # 06 Y:2006 06 2006 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $117,767 $838,833 Not Implemented
OK0727 # 07 Y:2006 07 2006 INSULATE BARE EQUIPMENT $14,689 $7,635 Implemented
OK0727 # 08 Y:2006 08 2006 INSTALL OCCUPANCY SENSORS $676 $535 Not Implemented
IC0105 # 01 Y:2005 01 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $60,808 $100,000 Implemented
IC0105 # 02 Y:2005 02 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,211 $2,000 Implemented
IC0105 # 03 Y:2005 03 2005 REPAIR AND ELIMINATE STEAM LEAKS $17,271 $3,900 Implemented
IC0105 # 04 Y:2005 04 2005 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $12,910 $900 Not Implemented
IC0105 # 05 Y:2005 05 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,728 $42,000 Not Implemented
IC0105 # 06 Y:2005 06 2005 INSTALL OCCUPANCY SENSORS $94 $713 Not Implemented
IC0105 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $255 $714 Not Implemented
IC0105 # 08 Y:2005 08 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,344 $13,017 Not Implemented
IC0087 # 01 Y:2004 01 2004 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $210,887 $2,078 Not Implemented
IC0087 # 02 Y:2004 02 2004 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $135,849 $18,578 Not Implemented
IC0087 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $216,557 $4,311 Implemented
IC0087 # 04 Y:2004 04 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $43,578 $6,900 Implemented
IC0087 # 05 Y:2004 05 2004 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $53,985 $1,560 Not Implemented
IC0087 # 06 Y:2004 06 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,571 $8,465 Implemented
IC0087 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $28,383 $56,925 Implemented
IC0087 # 08 Y:2004 08 2004 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $4,114 $609,500 Not Implemented