Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 2899 | Chemical Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0871 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,500 | $12,000 | Not Implemented |
GT0871 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,563 | $17,696 | Implemented |
GT0871 # 06 Y:2010 | 06 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,535 | $11,000 | Not Implemented |
GT0871 # 05 Y:2010 | 05 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $3,635 | $22,000 | Not Implemented |
GT0871 # 04 Y:2010 | 04 | 2010 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $119,576 | $25,000 | Not Implemented |
GT0871 # 03 Y:2010 | 03 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $40,118 | $23,620 | Implemented |
GT0871 # 02 Y:2010 | 02 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,114 | $23,200 | Not Implemented |
GT0871 # 01 Y:2010 | 01 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,860 | $768 | Implemented |
GT0854 # 02 Y:2008 | 02 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,745 | $3,000 | Implemented |
GT0854 # 09 Y:2008 | 09 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,015 | $35,125 | Implemented |
GT0854 # 08 Y:2008 | 08 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $14,260 | $23,000 | Implemented |
GT0854 # 07 Y:2008 | 07 | 2008 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,141 | $10,000 | Not Implemented |
GT0854 # 06 Y:2008 | 06 | 2008 | REDUCE EXCESSIVE BOILER BLOWDOWN | $4,690 | $0 | Not Implemented |
GT0854 # 05 Y:2008 | 05 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,990 | $80,000 | Not Implemented |
GT0854 # 04 Y:2008 | 04 | 2008 | REPAIR OR REPLACE STEAM TRAPS | $25,424 | $5,000 | Implemented |
GT0854 # 03 Y:2008 | 03 | 2008 | INCREASE AMOUNT OF CONDENSATE RETURNED | $5,970 | $2,500 | Not Implemented |
GT0854 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,568 | $700 | Implemented |
GT0510 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $740 | $2,160 | Not Implemented |
GT0510 # 07 Y:1993 | 07 | 1993 | REPAIR AND ELIMINATE STEAM LEAKS | $20,590 | $2,400 | Implemented |
GT0510 # 06 Y:1993 | 06 | 1993 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $134,080 | $250,000 | Implemented |
GT0510 # 05 Y:1993 | 05 | 1993 | INCREASE AMOUNT OF CONDENSATE RETURNED | $10,100 | $6,500 | Not Implemented |
GT0510 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,880 | $5,260 | Implemented |
GT0510 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,250 | $500 | Implemented |
GT0510 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $700 | $930 | Not Implemented |
GT0510 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,220 | $9,990 | Not Implemented |