Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
69
matching recommendationsSIC | 29 | Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0690 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $292 | $706 | Implemented |
OK0690 # 01 Y:2004 | 01 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,252 | $21,080 | Implemented |
OK0690 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $8,325 | $800 | Implemented |
OK0650 # 01 Y:2002 | 01 | 2002 | INSTALL OCCUPANCY SENSORS | $1,203 | $1,190 | Implemented |
OK0650 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,073 | $100 | Implemented |
OK0650 # 04 Y:2002 | 04 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $133,632 | $206,750 | Not Implemented |
OK0650 # 06 Y:2002 | 06 | 2002 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $1,550,000 | $150,000 | Not Implemented |
OK0650 # 03 Y:2002 | 03 | 2002 | USE OPTIMUM THICKNESS INSULATION | $56,715 | $16,956 | n/a |
OK0650 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $4,021,800 | $30,000,000 | Not Implemented |
OK0492 # 04 Y:1996 | 04 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,800 | $0 | Implemented |
OK0492 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $522 | $468 | Not Implemented |
OK0492 # 02 Y:1996 | 02 | 1996 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,502 | $500 | Implemented |
OK0492 # 01 Y:1996 | 01 | 1996 | INSULATE BARE EQUIPMENT | $2,709 | $3,419 | Implemented |
OK0431 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,773 | $0 | Not Implemented |
OK0431 # 01 Y:1994 | 01 | 1994 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,728 | $4,000 | Not Implemented |
OK0431 # 02 Y:1994 | 02 | 1994 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $3,276 | $11,000 | Not Implemented |
OK0431 # 04 Y:1994 | 04 | 1994 | USE PHOTOCELL CONTROLS | $783 | $180 | Not Implemented |
OK0431 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $694 | $1,520 | Not Implemented |
OK0431 # 06 Y:1994 | 06 | 1994 | INSULATE BARE EQUIPMENT | $79 | $125 | Not Implemented |
OK0431 # 07 Y:1994 | 07 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $26 | $0 | Not Implemented |
OK0425 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $467 | $1,920 | Not Implemented |
OK0425 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,846 | $11,619 | Implemented |
OK0425 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,605 | $0 | Implemented |
OK0425 # 01 Y:1994 | 01 | 1994 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,247,712 | $4,815,000 | Not Implemented |
OK0194 # 02 Y:1986 | 02 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,873 | $500 | Implemented |