Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
42
matching recommendationsSIC | 29 | Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1045 # 10 Y:2022 | 10 | 2022 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,319 | $15,000 | Not Implemented |
UD1045 # 09 Y:2022 | 09 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,617 | $32,900 | Not Implemented |
UD1045 # 07 Y:2022 | 07 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,938 | $35,826 | Not Implemented |
UD1045 # 08 Y:2022 | 08 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,184 | $2,200 | Not Implemented |
UD1045 # 05 Y:2022 | 05 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,284 | $453 | Not Implemented |
UD1045 # 06 Y:2022 | 06 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $720 | $1,000 | Not Implemented |
UD1045 # 03 Y:2022 | 03 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,090 | $27,500 | Not Implemented |
UD1045 # 01 Y:2022 | 01 | 2022 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,883 | $0 | Not Implemented |
UD1045 # 02 Y:2022 | 02 | 2022 | COMBINE UTILITY METERS | $1,103 | $0 | Not Implemented |
UD1045 # 04 Y:2022 | 04 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,605 | $600 | Not Implemented |
UD0897 # 09 Y:2014 | 09 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $22,517 | $48,000 | Not Implemented |
UD0897 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $755 | $1,000 | Implemented |
UD0897 # 02 Y:2014 | 02 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $405 | $0 | Not Implemented |
UD0897 # 01 Y:2014 | 01 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,780 | $0 | Not Implemented |
UD0897 # 04 Y:2014 | 04 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,897 | $5,000 | Not Implemented |
UD0897 # 05 Y:2014 | 05 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $765 | $0 | Implemented |
UD0897 # 07 Y:2014 | 07 | 2014 | ADD AREA LIGHTING SWITCHES | $664 | $600 | Not Implemented |
UD0897 # 08 Y:2014 | 08 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $142 | $900 | Not Implemented |
UD0897 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,409 | $5,020 | Not Implemented |
UD0709 # 01 Y:2005 | 01 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,133 | $0 | Not Implemented |
UD0709 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,708 | $3,213 | Not Implemented |
UD0709 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $3,977 | $4,500 | Implemented |
UD0709 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,529 | $0 | Implemented |
UD0709 # 03 Y:2005 | 03 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $13,847 | $40,000 | Not Implemented |
UD0709 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,549 | $34,600 | Not Implemented |