Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

144

matching recommendations
Reset
SIC 2911 Petroleum Refining
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0235 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $18,187 $21,040 Not Implemented
UL0235 # 02 Y:1999 02 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $5,509 $2,875 Implemented
TN0654 # 01 Y:1999 01 1999 BURN A LESS EXPENSIVE GRADE OF FUEL $144,460 $25,120 Implemented
TN0654 # 02 Y:1999 02 1999 BURN A LESS EXPENSIVE GRADE OF FUEL $68,850 $265,960 Not Implemented
TN0654 # 03 Y:1999 03 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $29,975 $18,950 Implemented
TN0654 # 04 Y:1999 04 1999 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,840 $22,720 Implemented
TN0654 # 05 Y:1999 05 1999 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $9,000 $16,000 Implemented
TN0654 # 06 Y:1999 06 1999 TREAT AND REUSE RINSE WATERS $3,925 $9,680 Not Implemented
TN0654 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $2,730 $3,310 Implemented
WI0243 # 01 Y:1995 01 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $4,132 $10,000 Not Implemented
WI0243 # 02 Y:1995 02 1995 INSTALL TIMERS AND/OR THERMOSTATS $6,975 $400 Implemented
WI0243 # 03 Y:1995 03 1995 REPLACE BOILER $3,712 $12,000 Not Implemented
WI0243 # 04 Y:1995 04 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,111 $6,000 Not Implemented
WI0243 # 05 Y:1995 05 1995 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,773 $1,500 Implemented
WI0243 # 06 Y:1995 06 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,126 $538 Not Implemented
WI0243 # 07 Y:1995 07 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $898 $1,796 Implemented
WI0243 # 08 Y:1995 08 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $445 $700 Not Implemented
WI0243 # 09 Y:1995 09 1995 INSULATE BARE EQUIPMENT $248 $672 Not Implemented
WI0243 # 10 Y:1995 10 1995 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $13,399 $9,000 Not Implemented
GT0544 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,820 $20,170 Implemented
GT0544 # 02 Y:1994 02 1994 REPAIR AND ELIMINATE STEAM LEAKS $5,240 $800 Implemented
GT0544 # 03 Y:1994 03 1994 RECOVER WASTE HEAT FROM EQUIPMENT $77,700 $212,000 Not Implemented
GT0544 # 04 Y:1994 04 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $18,160 $13,550 Implemented
GT0544 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $3,090 $2,665 Not Implemented
GT0544 # 06 Y:1994 06 1994 INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK $8,610 $13,750 Not Implemented