Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
911
matching recommendationsSIC | 295 | Asphalt Paving And Roofing Materials |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0453 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,700 | $12,150 | Implemented |
UD0849 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $62,282 | $15,816 | Not Implemented |
UD0849 # 02 Y:2012 | 02 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,445 | $0 | Not Implemented |
UD0849 # 03 Y:2012 | 03 | 2012 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $14,632 | $0 | Not Implemented |
UD0849 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,199 | $500 | Not Implemented |
UD0849 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,530 | $1,000 | Not Implemented |
UD0849 # 06 Y:2012 | 06 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $34,045 | $44,000 | Not Implemented |
UD0849 # 07 Y:2012 | 07 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,241 | $11,000 | Not Implemented |
UD0849 # 08 Y:2012 | 08 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,274 | $2,000 | Not Implemented |
IA0469 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,826 | $2,900 | Implemented |
IA0469 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $509 | $522 | Implemented |
IA0469 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,107 | $840 | Not Implemented |
IA0469 # 04 Y:2011 | 04 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $880 | $1,922 | Implemented |
IA0469 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $105 | $300 | Implemented |
IA0469 # 06 Y:2011 | 06 | 2011 | USE OPTIMUM THICKNESS INSULATION | $16,511 | $17,910 | Not Implemented |
IA0469 # 07 Y:2011 | 07 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $280 | $383 | Not Implemented |
IA0469 # 08 Y:2011 | 08 | 2011 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $9,865 | $1,500 | Implemented |
IA0468 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $384 | $361 | Implemented |
IA0468 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,516 | $20,588 | Not Implemented |
IA0468 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $877 | $240 | Implemented |
IA0468 # 04 Y:2011 | 04 | 2011 | USE OPTIMUM THICKNESS INSULATION | $1,433 | $740 | Implemented |
IA0468 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $453 | $23 | Implemented |
IA0468 # 06 Y:2011 | 06 | 2011 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,025 | $150 | Implemented |
IA0468 # 07 Y:2011 | 07 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,116 | $3,625 | Not Implemented |
IA0468 # 08 Y:2011 | 08 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $21,972 | $10,000 | Not Implemented |