Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
315
matching recommendationsSIC | 299 | Misc. Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0524 # 06 Y:2007 | 06 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,300 | $280 | Implemented |
AM0524 # 07 Y:2007 | 07 | 2007 | USE SYNTHETIC LUBRICANT | $810 | $0 | Implemented |
AM0524 # 08 Y:2007 | 08 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $300 | $0 | Implemented |
GT0830 # 01 Y:2006 | 01 | 2006 | USE SYNTHETIC LUBRICANT | $1,678 | $0 | Implemented |
GT0830 # 02 Y:2006 | 02 | 2006 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $140,680 | $87,010 | Implemented |
GT0830 # 03 Y:2006 | 03 | 2006 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $8,256 | $36,000 | Not Implemented |
GT0830 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,756 | $5,548 | Implemented |
GT0830 # 05 Y:2006 | 05 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $9,422 | $1,250 | Not Implemented |
GT0830 # 06 Y:2006 | 06 | 2006 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $1,790 | $0 | Not Implemented |
GT0830 # 07 Y:2006 | 07 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,966 | $4,500 | Not Implemented |
GT0830 # 08 Y:2006 | 08 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $918 | $0 | Implemented |
GT0830 # 09 Y:2006 | 09 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,744 | $5,630 | Not Implemented |
LL0244 # 01 Y:2006 | 01 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $490,346 | $849,320 | Not Implemented |
LL0244 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $240,584 | $34,600 | Implemented |
LL0244 # 03 Y:2006 | 03 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $72,332 | $3,042 | Implemented |
LL0244 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,933 | $122,080 | Not Implemented |
LL0244 # 05 Y:2006 | 05 | 2006 | INSTALL OCCUPANCY SENSORS | $3,024 | $300 | Not Implemented |
LL0244 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $2,093 | $313 | Implemented |
LL0244 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $1,716 | $913 | Implemented |
LL0244 # 08 Y:2006 | 08 | 2006 | USE PHOTOCELL CONTROLS | $1,606 | $150 | Not Implemented |
LL0172 # 01 Y:2003 | 01 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $390,733 | $195,000 | Implemented |
LL0172 # 02 Y:2003 | 02 | 2003 | ELIMINATE COMBUSTIBLE GAS IN FLUE GAS | $197,664 | $250,000 | Not Implemented |
LL0172 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $101,833 | $7,757 | Not Implemented |
LL0172 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $87,485 | $28,240 | Implemented |
LL0172 # 05 Y:2003 | 05 | 2003 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $65,820 | $312,701 | Not Implemented |