Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 299 | Misc. Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1074 # 01 Y:2022 | 01 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $362 | $0 | Not Implemented |
OK1074 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $187 | Not Implemented |
OK1074 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,000 | $2,520 | Implemented |
OK1074 # 04 Y:2022 | 04 | 2022 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,213 | $895 | Implemented |
OK1074 # 05 Y:2022 | 05 | 2022 | INSULATE BARE EQUIPMENT | $1,700 | $611 | Not Implemented |
OK1048 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,153 | $4,000 | Not Implemented |
OK1048 # 05 Y:2021 | 05 | 2021 | OPTIMIZE PLANT POWER FACTOR | $22,294 | $15,000 | Not Implemented |
OK1048 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $2,257 | $3,150 | Implemented |
OK1048 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,475 | $13,356 | Implemented |
OK1048 # 01 Y:2021 | 01 | 2021 | REPAIR AND ELIMINATE STEAM LEAKS | $37,041 | $2,860 | Implemented |
OK0650 # 06 Y:2002 | 06 | 2002 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $1,550,000 | $150,000 | Not Implemented |
OK0650 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $4,021,800 | $30,000,000 | Not Implemented |
OK0650 # 04 Y:2002 | 04 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $133,632 | $206,750 | Not Implemented |
OK0650 # 03 Y:2002 | 03 | 2002 | USE OPTIMUM THICKNESS INSULATION | $56,715 | $16,956 | n/a |
OK0650 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,073 | $100 | Implemented |
OK0650 # 01 Y:2002 | 01 | 2002 | INSTALL OCCUPANCY SENSORS | $1,203 | $1,190 | Implemented |
OK0425 # 01 Y:1994 | 01 | 1994 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,247,712 | $4,815,000 | Not Implemented |
OK0425 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,846 | $11,619 | Implemented |
OK0425 # 03 Y:1994 | 03 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,605 | $0 | Implemented |
OK0425 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $467 | $1,920 | Not Implemented |
OK0194 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $540 | $1,475 | Implemented |
OK0194 # 02 Y:1986 | 02 | 1986 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $1,873 | $500 | Implemented |
OK0194 # 01 Y:1986 | 01 | 1986 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $58,564 | $35,000 | Implemented |
OK0189 # 06 Y:1986 | 06 | 1986 | INSTALL DE-AERATOR IN PLACE OF CONDENSATE TANK | $6,444 | $30,000 | Not Implemented |
OK0189 # 05 Y:1986 | 05 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,672 | $21,000 | Not Implemented |