Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
132
matching recommendationsSIC | 2992 | Lubricating Oils And Greases |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA3008 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $6,109 | $337 | Implemented |
DL0056 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM TEMPERATURE | $7,644 | $100 | Implemented |
DL0056 # 05 Y:2010 | 05 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,000 | $300 | Implemented |
DL0056 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $184,560 | $1,200,000 | Implemented |
DL0045 # 09 Y:2010 | 09 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,229 | $100,000 | Implemented |
DL0045 # 06 Y:2010 | 06 | 2010 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $3,560 | $2,000 | Implemented |
DL0045 # 02 Y:2010 | 02 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,204 | $0 | Implemented |
CO0631 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,020 | $5,662 | Implemented |
CO0631 # 01 Y:2010 | 01 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,000 | $19,665 | Implemented |
CO0631 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,360 | $3,977 | Implemented |
CO0631 # 04 Y:2010 | 04 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,920 | $27,104 | Implemented |
CO0631 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,710 | $8,757 | Implemented |
CO0631 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,020 | $37,620 | Implemented |
CO0631 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $600 | $3,108 | Implemented |
BD0338 # 07 Y:2007 | 07 | 2007 | REPLACE BOILER | $36,792 | $110,001 | Implemented |
UM0322 # 01 Y:2007 | 01 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $43,338 | $0 | Implemented |
UM0322 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $14,251 | $5,900 | Implemented |
UM0322 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $6,308 | $6,013 | Implemented |
UM0322 # 05 Y:2007 | 05 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,439 | $1,000 | Implemented |
UM0322 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $913 | $600 | Implemented |
UM0322 # 10 Y:2007 | 10 | 2007 | USE PHOTOCELL CONTROLS | $549 | $190 | Implemented |
OR0517 # 03 Y:2007 | 03 | 2007 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $18,000 | $0 | Implemented |
OR0517 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $0 | Implemented |
OR0517 # 04 Y:2007 | 04 | 2007 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $17,200 | $500 | Implemented |
OR0517 # 06 Y:2007 | 06 | 2007 | INSULATE BARE EQUIPMENT | $6,100 | $3,750 | Implemented |