Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,818
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0115 # 08 Y:2001 | 08 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $14,780 | $9,400 | Implemented |
BD0182 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,936 | $700 | Implemented |
BD0182 # 06 Y:2001 | 06 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,069 | $5,000 | Implemented |
BD0182 # 11 Y:2001 | 11 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $14,925 | $1,000 | Implemented |
BD0182 # 12 Y:2001 | 12 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $6,200 | $321 | Implemented |
WI0391 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,794 | $90 | Implemented |
WI0391 # 03 Y:2001 | 03 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $393 | $640 | Implemented |
SD0270 # 01 Y:2001 | 01 | 2001 | REDESIGN PROCESS | $182,520 | $35,000 | Implemented |
SD0270 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $21,642 | $15,000 | Implemented |
SD0270 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,189 | $800 | Implemented |
SD0270 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,077 | $36,000 | Implemented |
SD0270 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $51,823 | $103,000 | Implemented |
SD0270 # 07 Y:2001 | 07 | 2001 | INSTALL SKYLIGHTS | $7,878 | $12,500 | Implemented |
SD0270 # 09 Y:2001 | 09 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $32,522 | $5,000 | Implemented |
SD0270 # 10 Y:2001 | 10 | 2001 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $3,170 | $1,500 | Implemented |
SD0270 # 11 Y:2001 | 11 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $648 | $0 | Implemented |
SD0270 # 12 Y:2001 | 12 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $25,910 | $15,000 | Implemented |
SD0270 # 13 Y:2001 | 13 | 2001 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $35,880 | $0 | Implemented |
NC0210 # 02 Y:2001 | 02 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $809 | $592 | Implemented |
MS0175 # 01 Y:2000 | 01 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,400 | $50 | Implemented |
AM0388 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PLANT POWER FACTOR | $22,600 | $23,800 | Implemented |
AM0388 # 02 Y:2001 | 02 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $3,700 | $0 | Implemented |
AM0388 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,550 | $500 | Implemented |
AM0388 # 06 Y:2001 | 06 | 2001 | USE SYNTHETIC LUBRICANT | $930 | $0 | Implemented |
AM0388 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $745 | $310 | Implemented |