Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
754
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0814 # 09 Y:2010 | 09 | 2010 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $8,568 | $3,000 | Implemented |
UD0814 # 10 Y:2010 | 10 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,017 | $400 | Implemented |
UD0814 # 11 Y:2010 | 11 | 2010 | INSULATE BARE EQUIPMENT | $1,111 | $807 | Not Implemented |
UD0814 # 12 Y:2010 | 12 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,484 | $0 | Implemented |
UD0798 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $177,970 | $480,000 | Not Implemented |
UD0798 # 02 Y:2009 | 02 | 2009 | INSULATE BARE EQUIPMENT | $56,464 | $62,640 | Not Implemented |
UD0798 # 03 Y:2009 | 03 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,050 | $0 | Not Implemented |
UD0798 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,344 | $62,000 | Implemented |
UD0798 # 05 Y:2009 | 05 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $22,669 | $32,084 | Not Implemented |
UD0798 # 06 Y:2009 | 06 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $21,417 | $0 | Implemented |
UD0798 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,830 | $25,242 | Not Implemented |
UD0798 # 08 Y:2009 | 08 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $7,626 | $0 | Implemented |
UD0798 # 09 Y:2009 | 09 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,462 | $0 | Implemented |
UD0798 # 10 Y:2009 | 10 | 2009 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,678 | $0 | Implemented |
UD0798 # 11 Y:2009 | 11 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $341 | $0 | Implemented |
UD0753 # 01 Y:2007 | 01 | 2007 | DEVELOP STANDARD OPERATING PROCEDURES | $98,450 | $3,040 | Implemented |
UD0753 # 02 Y:2007 | 02 | 2007 | REDUCE VENTILATION AIR | $67,600 | $19,800 | Implemented |
UD0753 # 03 Y:2007 | 03 | 2007 | REDUCE VENTILATION AIR | $36,200 | $10,000 | Not Implemented |
UD0753 # 04 Y:2007 | 04 | 2007 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $35,807 | $30,000 | Not Implemented |
UD0753 # 05 Y:2007 | 05 | 2007 | INSULATE BARE EQUIPMENT | $11,994 | $7,875 | Implemented |
UD0753 # 06 Y:2007 | 06 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $10,800 | $15,600 | Implemented |
UD0753 # 07 Y:2007 | 07 | 2007 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $8,390 | $15,000 | Implemented |
UD0753 # 08 Y:2007 | 08 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,105 | $16,500 | Not Implemented |
UD0753 # 09 Y:2007 | 09 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,816 | $0 | Implemented |
UD0753 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,007 | $0 | Not Implemented |