IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

783

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0640 # 04 Y:1998 04 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,140 $2,765 Implemented
TN0640 # 05 Y:1998 05 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,110 $830 Not Implemented
TN0640 # 06 Y:1998 06 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $85 $50 Implemented
ND0304 # 01 Y:1998 01 1998 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $76,325 $90,000 Implemented
ND0304 # 02 Y:1998 02 1998 RECOVER AND REUSE WASTE MATERIAL $15,525 $50,000 Implemented
ND0304 # 03 Y:1998 03 1998 INSTALL SKYLIGHTS $3,717 $513 Implemented
ND0304 # 04 Y:1998 04 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $623 $608 Not Implemented
ND0304 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,063 $560 Implemented
ND0304 # 06 Y:1998 06 1998 RECOVER WASTE HEAT FROM EQUIPMENT $627 $700 Implemented
ND0304 # 07 Y:1998 07 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $373 $200 Implemented
ND0304 # 08 Y:1998 08 1998 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $972 $2,880 Implemented
ND0304 # 09 Y:1998 09 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $128 $908 Not Implemented
ND0304 # 10 Y:1998 10 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $459 $50 Not Implemented
ND0304 # 11 Y:1998 11 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $377 $165 Not Implemented
ND0304 # 12 Y:1998 12 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $13 $23 Implemented
AR0142 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $311 $655 Implemented
AR0142 # 02 Y:1998 02 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $866 $0 Implemented
AR0142 # 03 Y:1998 03 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $272 $186 Implemented
AR0142 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,472 $50 Implemented
AR0142 # 05 Y:1998 05 1998 INSTALL / REPAIR INSULATION ON STEAM LINES $757 $652 Implemented
AR0142 # 06 Y:1998 06 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $3,263 $8,000 Not Implemented
AR0142 # 07 Y:1998 07 1998 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $374 $210 Not Implemented
AR0142 # 08 Y:1998 08 1998 $97,959 $21,200 Not Implemented
WI0328 # 01 Y:1998 01 1998 $18,977 $0 Implemented
WI0328 # 02 Y:1998 02 1998 $3,491 $1,250 Not Implemented