Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
445
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0331 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,975 | $8,500 | Not Implemented |
WI0331 # 05 Y:1998 | 05 | 1998 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,218 | $0 | Not Implemented |
WI0331 # 06 Y:1998 | 06 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,729 | $0 | Not Implemented |
WI0331 # 07 Y:1998 | 07 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,249 | $300 | Implemented |
WI0331 # 08 Y:1998 | 08 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $897 | $608 | Not Implemented |
WI0320 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $98,187 | $100,000 | Not Implemented |
WI0320 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $4,771 | $600 | Not Implemented |
WI0320 # 03 Y:1998 | 03 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,933 | $6,400 | Not Implemented |
WI0320 # 04 Y:1998 | 04 | 1998 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,532 | $0 | Not Implemented |
WI0320 # 05 Y:1998 | 05 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,433 | $7,000 | Not Implemented |
WI0320 # 06 Y:1998 | 06 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $650 | $740 | Implemented |
WI0265 # 01 Y:1996 | 01 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $35,546 | $60,000 | Implemented |
WI0265 # 02 Y:1996 | 02 | 1996 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,889 | $0 | Not Implemented |
WI0265 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,667 | $8,000 | Not Implemented |
WI0265 # 04 Y:1996 | 04 | 1996 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $6,626 | $27,600 | Not Implemented |
WI0265 # 05 Y:1996 | 05 | 1996 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $3,490 | $6,500 | Implemented |
WI0265 # 06 Y:1996 | 06 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $2,039 | $6,400 | Implemented |
WI0265 # 07 Y:1996 | 07 | 1996 | RECOVER AND REUSE COOLING WATER | $1,750 | $6,000 | Not Implemented |
WI0265 # 08 Y:1996 | 08 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $954 | $4,000 | Not Implemented |
WI0265 # 09 Y:1996 | 09 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,135 | $0 | Not Implemented |
WI0265 # 10 Y:1996 | 10 | 1996 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $718 | $0 | Not Implemented |
WI0265 # 11 Y:1996 | 11 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $500 | $2,000 | Not Implemented |
WI0171 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,629 | $90,000 | Not Implemented |
WI0171 # 02 Y:1993 | 02 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,354 | $1,769 | Not Implemented |
WI0171 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,095 | $1,481 | Not Implemented |