Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,765
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0488 # 11 Y:2014 | 11 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $327 | $221 | Implemented |
WV0488 # 12 Y:2014 | 12 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $134 | $150 | Not Implemented |
WV0485 # 01 Y:2014 | 01 | 2014 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,434 | $1,000 | Not Implemented |
WV0485 # 02 Y:2014 | 02 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $9,166 | $12,500 | Not Implemented |
WV0485 # 03 Y:2014 | 03 | 2014 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,371 | $10,550 | Not Implemented |
WV0485 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $5,211 | $2,981 | Implemented |
WV0485 # 05 Y:2014 | 05 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,703 | $500 | Implemented |
WV0485 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,806 | $4,815 | Not Implemented |
WV0485 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,038 | $175 | Implemented |
WV0485 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $2,805 | $3,000 | Implemented |
WV0485 # 09 Y:2014 | 09 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,922 | $1,719 | Not Implemented |
WV0485 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,635 | $4,433 | Not Implemented |
WV0485 # 11 Y:2014 | 11 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $1,516 | $696 | Implemented |
WV0485 # 12 Y:2014 | 12 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $691 | $426 | Implemented |
UD0896 # 01 Y:2014 | 01 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $74 | $0 | Implemented |
UD0896 # 02 Y:2014 | 02 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $31,308 | $10,500 | Not Implemented |
UD0896 # 03 Y:2014 | 03 | 2014 | MINIMIZE WATER USAGE | $7,067 | $8,000 | Not Implemented |
UD0896 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $683 | $500 | Not Implemented |
UD0896 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $22 | $0 | Not Implemented |
UD0896 # 06 Y:2014 | 06 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $8,000 | Not Implemented |
UD0896 # 07 Y:2014 | 07 | 2014 | USE OPTIMUM THICKNESS INSULATION | $1,035 | $1,211 | Not Implemented |
UD0896 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $794 | $1,000 | Not Implemented |
UD0895 # 01 Y:2014 | 01 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $72,083 | $0 | Implemented |
UD0895 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,208 | $0 | Implemented |
UD0895 # 03 Y:2014 | 03 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $48,509 | $7,500 | Implemented |