Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
469
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0371 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,559 | $55,084 | Not Implemented |
SD0371 # 08 Y:2005 | 08 | 2005 | USE POWER DURING OFF-PEAK PERIODS | $31,048 | $0 | Not Implemented |
BD0295 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,724 | $0 | Implemented |
BD0295 # 05 Y:2005 | 05 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,487 | $3,000 | Implemented |
BD0295 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $14,253 | $2,875 | Implemented |
BD0295 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,391 | $900 | Implemented |
BD0295 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,254 | $8,470 | Implemented |
BD0295 # 01 Y:2005 | 01 | 2005 | AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED | $32,765 | $600 | Implemented |
WV0325 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $16,088 | $12,504 | Not Implemented |
WV0325 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,956 | $11,550 | Not Implemented |
WV0325 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,144 | $662 | Implemented |
WV0325 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,050 | $653 | Implemented |
WV0325 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,009 | $0 | Implemented |
WV0325 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,529 | $408 | Not Implemented |
WV0325 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $2,990 | $257 | Implemented |
WV0325 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,637 | $420 | Implemented |
WV0325 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $851 | $426 | Implemented |
WV0325 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $832 | $2,612 | Implemented |
WV0325 # 11 Y:2005 | 11 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $775 | $521 | Not Implemented |
WV0325 # 12 Y:2005 | 12 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $260 | Implemented |
WV0325 # 13 Y:2005 | 13 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $276 | Not Implemented |
TA0101 # 10 Y:2005 | 10 | 2005 | INSULATE BARE EQUIPMENT | $255 | $360 | Implemented |
TA0101 # 09 Y:2005 | 09 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $275 | $0 | Not Implemented |
TA0101 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $395 | $100 | Implemented |
TA0101 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $665 | $200 | Implemented |