Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,583
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0027 # 11 Y:1994 | 11 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,333 | $3,593 | Not Implemented |
SF0025 # 01 Y:1994 | 01 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $80,193 | $254,208 | Implemented |
SF0025 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,769 | $10,699 | Not Implemented |
SF0025 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $885 | $2,100 | Implemented |
SF0025 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,419 | $0 | Not Implemented |
SF0025 # 05 Y:1994 | 05 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $488 | $750 | Not Implemented |
SF0025 # 06 Y:1994 | 06 | 1994 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $821 | $328 | Not Implemented |
SF0025 # 07 Y:1994 | 07 | 1994 | INSTALL SKYLIGHTS | $605 | $1,285 | Not Implemented |
SF0025 # 08 Y:1994 | 08 | 1994 | INSTALL OCCUPANCY SENSORS | $1,221 | $2,716 | Not Implemented |
SD0078 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,072 | $2,240 | Implemented |
SD0078 # 02 Y:1994 | 02 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,864 | $100 | Implemented |
SD0078 # 03 Y:1994 | 03 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,891 | $832 | Not Implemented |
SD0078 # 04 Y:1994 | 04 | 1994 | INSULATE BARE EQUIPMENT | $152 | $153 | Not Implemented |
SD0078 # 05 Y:1994 | 05 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $1,549 | $300 | Not Implemented |
SD0078 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,867 | $2,438 | Implemented |
SD0078 # 07 Y:1994 | 07 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,441 | $4,196 | Not Implemented |
SD0078 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $295 | $104 | Implemented |
SD0078 # 09 Y:1994 | 09 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $405 | $150 | Not Implemented |
SD0078 # 10 Y:1994 | 10 | 1994 | USE PHOTOCELL CONTROLS | $247 | $115 | Not Implemented |
SD0078 # 11 Y:1994 | 11 | 1994 | INSTALL OCCUPANCY SENSORS | $1,241 | $800 | Implemented |
SD0071 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $27,894 | $27,500 | Implemented |
SD0071 # 02 Y:1994 | 02 | 1994 | INSULATE BARE EQUIPMENT | $473 | $136 | Implemented |
SD0071 # 03 Y:1994 | 03 | 1994 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $15,214 | $24,880 | Implemented |
SD0071 # 04 Y:1994 | 04 | 1994 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $16,815 | $8,515 | Not Implemented |
SD0071 # 05 Y:1994 | 05 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,613 | $0 | Implemented |