Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,583

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0027 # 11 Y:1994 11 1994 OPTIMIZE PLANT POWER FACTOR $2,333 $3,593 Not Implemented
SF0025 # 01 Y:1994 01 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $80,193 $254,208 Implemented
SF0025 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,769 $10,699 Not Implemented
SF0025 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $885 $2,100 Implemented
SF0025 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,419 $0 Not Implemented
SF0025 # 05 Y:1994 05 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $488 $750 Not Implemented
SF0025 # 06 Y:1994 06 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $821 $328 Not Implemented
SF0025 # 07 Y:1994 07 1994 INSTALL SKYLIGHTS $605 $1,285 Not Implemented
SF0025 # 08 Y:1994 08 1994 INSTALL OCCUPANCY SENSORS $1,221 $2,716 Not Implemented
SD0078 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,072 $2,240 Implemented
SD0078 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,864 $100 Implemented
SD0078 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,891 $832 Not Implemented
SD0078 # 04 Y:1994 04 1994 INSULATE BARE EQUIPMENT $152 $153 Not Implemented
SD0078 # 05 Y:1994 05 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,549 $300 Not Implemented
SD0078 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,867 $2,438 Implemented
SD0078 # 07 Y:1994 07 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $4,441 $4,196 Not Implemented
SD0078 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $295 $104 Implemented
SD0078 # 09 Y:1994 09 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $405 $150 Not Implemented
SD0078 # 10 Y:1994 10 1994 USE PHOTOCELL CONTROLS $247 $115 Not Implemented
SD0078 # 11 Y:1994 11 1994 INSTALL OCCUPANCY SENSORS $1,241 $800 Implemented
SD0071 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $27,894 $27,500 Implemented
SD0071 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $473 $136 Implemented
SD0071 # 03 Y:1994 03 1994 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $15,214 $24,880 Implemented
SD0071 # 04 Y:1994 04 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,815 $8,515 Not Implemented
SD0071 # 05 Y:1994 05 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,613 $0 Implemented