Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0268 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,666 | $30,813 | Not Implemented |
UD0397 # 01 Y:1993 | 01 | 1993 | COMBINE UTILITY METERS | $838 | $200 | Implemented |
UD0397 # 02 Y:1993 | 02 | 1993 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,462 | $100 | Implemented |
UD0397 # 03 Y:1993 | 03 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $445 | $20 | Implemented |
CO0270 # 01 Y:1993 | 01 | 1993 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $2,400 | $250 | Implemented |
CO0270 # 02 Y:1993 | 02 | 1993 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $14,790 | $16,720 | Not Implemented |
CO0270 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,020 | $2,500 | Implemented |
CO0270 # 04 Y:1993 | 04 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,450 | $2,850 | Implemented |
CO0271 # 01 Y:1993 | 01 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $34,060 | $400 | Implemented |
CO0271 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,640 | $400 | Implemented |
CO0271 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,260 | $2,500 | Implemented |
CO0271 # 04 Y:1993 | 04 | 1993 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,240 | $8,000 | Not Implemented |
CO0271 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,634 | $37,430 | Implemented |
SD0048 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,294 | $1,103 | Implemented |
SD0048 # 02 Y:1993 | 02 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $82,299 | $143,700 | Not Implemented |
SD0048 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,491 | $0 | Not Implemented |
SD0048 # 04 Y:1993 | 04 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $18,758 | $17,100 | Implemented |
SD0048 # 05 Y:1993 | 05 | 1993 | INSTALL SET-BACK TIMERS | $4,596 | $5,840 | Implemented |
SD0048 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $3,841 | $1,600 | Not Implemented |
SD0048 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,778 | $0 | Implemented |
MA0267 # 01 Y:1993 | 01 | 1993 | REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH | $5,832 | $301 | Implemented |
MA0267 # 02 Y:1993 | 02 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,246 | $4,899 | Implemented |
MA0267 # 03 Y:1993 | 03 | 1993 | INSULATE BARE EQUIPMENT | $2,483 | $250 | Implemented |
MA0267 # 04 Y:1993 | 04 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,483 | $0 | Not Implemented |
MA0267 # 05 Y:1993 | 05 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,235 | $4,181 | Not Implemented |