Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,617
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0535 # 01 Y:2016 | 01 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $324,317 | $112,783 | Implemented |
SD0535 # 02 Y:2016 | 02 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $110,770 | $402,000 | Not Implemented |
SD0535 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,449 | $42,926 | Implemented |
SD0535 # 04 Y:2016 | 04 | 2016 | OPTIMIZE PLANT POWER FACTOR | $9,321 | $3,181 | Not Implemented |
SD0535 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $7,184 | $6,400 | Implemented |
SD0535 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,708 | $200 | Not Implemented |
SD0535 # 07 Y:2016 | 07 | 2016 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $710 | $3,100 | Not Implemented |
SD0541 # 01 Y:2016 | 01 | 2016 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $51,914 | $30,240 | Not Implemented |
SD0541 # 02 Y:2016 | 02 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,692 | $1,454 | Implemented |
SD0541 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,995 | $4,078 | Implemented |
SD0541 # 04 Y:2016 | 04 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $976 | $324 | Implemented |
SD0541 # 05 Y:2016 | 05 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $13,025 | $17,000 | Implemented |
SD0541 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,362 | $200 | Not Implemented |
SD0541 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,385 | $2,800 | Implemented |
SD0541 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,632 | $12,913 | Implemented |
SD0541 # 09 Y:2016 | 09 | 2016 | USE PHOTOCELL CONTROLS | $6,061 | $14,800 | Implemented |
SD0541 # 10 Y:2016 | 10 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $7,037 | $270 | Implemented |
SD0541 # 11 Y:2016 | 11 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,842 | $1,098 | Implemented |
SF0479 # 01 Y:2016 | 01 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $796 | $70 | Not Implemented |
SF0479 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,025 | $210 | Implemented |
SF0479 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,397 | $4,166 | Implemented |
SF0479 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $846 | $2,490 | Implemented |
SF0479 # 05 Y:2016 | 05 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $24,263 | $204,396 | Not Implemented |
SD0523 # 01 Y:2016 | 01 | 2016 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $38,152 | $147,781 | Implemented |
SD0523 # 02 Y:2016 | 02 | 2016 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $17,463 | $69,877 | Implemented |