Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
760
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0244 # 02 Y:2003 | 02 | 2003 | SIZE TRUCKS TO JOB | $76,800 | $54,000 | Implemented |
UM0244 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $2,023 | $521 | Implemented |
UM0244 # 04 Y:2003 | 04 | 2003 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $26,499 | $51,860 | Not Implemented |
UM0244 # 01 Y:2003 | 01 | 2003 | ADOPT IN-HOUSE MATERIAL GENERATION | $101,745 | $30,000 | Not Implemented |
UM0244 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,934 | $13,221 | Not Implemented |
UM0244 # 03 Y:2003 | 03 | 2003 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $582 | $2,477 | Not Implemented |
MA0543 # 02 Y:2003 | 02 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $26,717 | $40,000 | Not Implemented |
MA0543 # 01 Y:2003 | 01 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $28,705 | $21,900 | n/a |
MA0543 # 05 Y:2003 | 05 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,953 | $12,400 | Not Implemented |
MA0543 # 07 Y:2003 | 07 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,408 | $527 | Implemented |
MA0543 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,265 | $0 | Not Implemented |
MA0543 # 06 Y:2003 | 06 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,571 | $12,104 | Implemented |
MA0543 # 04 Y:2003 | 04 | 2003 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $5,292 | $0 | Not Implemented |
BD0248 # 09 Y:2003 | 09 | 2003 | INSTALL OCCUPANCY SENSORS | $1,196 | $1,575 | Not Implemented |
BD0248 # 02 Y:2003 | 02 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,672 | $24,600 | n/a |
BD0248 # 01 Y:2003 | 01 | 2003 | INSULATE BARE EQUIPMENT | $48,696 | $13,832 | n/a |
BD0248 # 13 Y:2003 | 13 | 2003 | USE SYNTHETIC LUBRICANT | $74 | $200 | Not Implemented |
BD0248 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,847 | $4,555 | Implemented |
BD0248 # 17 Y:2003 | 17 | 2003 | AUTOMATE PAYROLL SYSTEM | $936 | $2,500 | Not Implemented |
BD0248 # 16 Y:2003 | 16 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $7,578 | $2,000 | Not Implemented |
BD0248 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,140 | $23,175 | Implemented |
BD0248 # 12 Y:2003 | 12 | 2003 | USE PHOTOCELL CONTROLS | $363 | $225 | Not Implemented |
BD0248 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,613 | $450 | Not Implemented |
BD0248 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,492 | $0 | Implemented |
BD0248 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,760 | $1,000 | Implemented |