Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
81
matching recommendationsSIC | 305 | Hose & Belting & Gaskets & Packing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0315 # 11 Y:2003 | 11 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,396 | $10,000 | Not Implemented |
SD0315 # 12 Y:2003 | 12 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $77,000 | $40,000 | Implemented |
SD0315 # 07 Y:2003 | 07 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,397 | $1,800 | Not Implemented |
SD0315 # 06 Y:2003 | 06 | 2003 | MAINTAIN MACHINES TO REDUCE LEAKS | $3,021 | $320 | Not Implemented |
SD0315 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $85,538 | $80,000 | Not Implemented |
SD0315 # 05 Y:2003 | 05 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,250 | $0 | Implemented |
SD0315 # 03 Y:2003 | 03 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $10,751 | $56 | Implemented |
SD0315 # 02 Y:2003 | 02 | 2003 | ISOLATE HOT OR COLD EQUIPMENT | $30,227 | $5,000 | Not Implemented |
SD0318 # 07 Y:2003 | 07 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,100 | $10,000 | Not Implemented |
SD0318 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $739 | $300 | Implemented |
SD0318 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,160 | $1,680 | Not Implemented |
SD0318 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,018 | $2,500 | Implemented |
SD0318 # 03 Y:2003 | 03 | 2003 | INSTALL SKYLIGHTS | $12,438 | $8,500 | Not Implemented |
SD0318 # 02 Y:2003 | 02 | 2003 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $12,503 | $25,000 | Not Implemented |
SD0318 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $44,624 | $76,000 | Not Implemented |
SD0270 # 06 Y:2001 | 06 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $51,823 | $103,000 | Implemented |
SD0270 # 01 Y:2001 | 01 | 2001 | REDESIGN PROCESS | $182,520 | $35,000 | Implemented |
SD0270 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $21,642 | $15,000 | Implemented |
SD0270 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,189 | $800 | Implemented |
SD0270 # 04 Y:2001 | 04 | 2001 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $63,100 | $90,000 | Not Implemented |
SD0270 # 05 Y:2001 | 05 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,077 | $36,000 | Implemented |
SD0270 # 07 Y:2001 | 07 | 2001 | INSTALL SKYLIGHTS | $7,878 | $12,500 | Implemented |
SD0270 # 08 Y:2001 | 08 | 2001 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $983,363 | $3,037,200 | Not Implemented |
SD0270 # 09 Y:2001 | 09 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $32,522 | $5,000 | Implemented |
SD0270 # 10 Y:2001 | 10 | 2001 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $3,170 | $1,500 | Implemented |