Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
SIC 305 Hose & Belting & Gaskets & Packing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0305 # 07 Y:2004 07 2004 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $320 $58 Implemented
NC0265 # 04 Y:2003 04 2003 RECOVER WASTE HEAT FROM EQUIPMENT $5,206 $1,100 Not Implemented
NC0265 # 03 Y:2003 03 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $7,348 $3,525 Implemented
NC0265 # 02 Y:2003 02 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $13,226 $24,506 Implemented
NC0265 # 01 Y:2003 01 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $23,793 $7,000 Implemented
NC0265 # 05 Y:2003 05 2003 ADJUST BURNERS FOR EFFICIENT OPERATION $7,094 $1,000 Implemented
NC0265 # 06 Y:2003 06 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,361 $0 Implemented
NC0265 # 07 Y:2003 07 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,469 $300 Implemented
NC0265 # 08 Y:2003 08 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $214 $50 Implemented
NC0265 # 09 Y:2003 09 2003 INSTALL OCCUPANCY SENSORS $100 $89 Implemented
NC0029 # 01 Y:1994 01 1994 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS $11,457 $153,000 Not Implemented
NC0029 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,131 $480 Implemented
NC0029 # 03 Y:1994 03 1994 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $14,345 $40,000 Implemented
NC0029 # 04 Y:1994 04 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,050 $520 Not Implemented
NC0029 # 05 Y:1994 05 1994 INSULATE BARE EQUIPMENT $562 $378 Not Implemented
TN0336 # 07 Y:1988 07 1988 INSULATE BARE EQUIPMENT $418 $274 Not Implemented
TN0336 # 01 Y:1988 01 1988 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $7,226 $19,980 Not Implemented
TN0336 # 02 Y:1988 02 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,139 $7,500 Implemented
TN0336 # 03 Y:1988 03 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,260 $830 Implemented
TN0336 # 04 Y:1988 04 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,494 $0 Implemented
TN0336 # 05 Y:1988 05 1988 ADJUST VENTS TO MINIMIZE ENERGY USE $890 $1,140 Implemented
TN0336 # 06 Y:1988 06 1988 IMPROVE LUBRICATION PRACTICES $795 $1,650 Not Implemented
TN0336 # 08 Y:1988 08 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $189 $180 Implemented
AT0064 # 04 Y:1987 04 1987 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,374 $4,200 Not Implemented
AT0064 # 03 Y:1987 03 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,391 $3,000 Not Implemented