IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,181

matching recommendations
Reset
SIC 305 Hose & Belting & Gaskets & Packing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0135 # 03 Y:1998 03 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $300 $0 Implemented
WV0135 # 04 Y:1998 04 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,310 $5,000 Not Implemented
WV0135 # 05 Y:1998 05 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,880 $53 Implemented
WV0135 # 06 Y:1998 06 1998 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $2,756 $250 Not Implemented
WV0135 # 07 Y:1998 07 1998 EXPAND OPERATIONS INTO UNUSED SPACE $2,400 $840 Implemented
MA0406 # 01 Y:1998 01 1998 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $3,022 $200 Implemented
MA0406 # 02 Y:1998 02 1998 UPGRADE CONTROLS ON COMPRESSORS $3,950 $1,785 Not Implemented
MA0406 # 03 Y:1998 03 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,323 $187 Implemented
MA0406 # 04 Y:1998 04 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $802 $541 Implemented
MA0406 # 05 Y:1998 05 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,955 $2,332 Not Implemented
MA0406 # 06 Y:1998 06 1998 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $3,045 $14,790 Not Implemented
MA0406 # 07 Y:1998 07 1998 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,468 $24,000 Implemented
MA0406 # 08 Y:1998 08 1998 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,070 $13,540 Not Implemented
AM0280 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $920 $25 Not Implemented
AM0280 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $570 $260 Implemented
AM0280 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $550 $400 Implemented
AM0280 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $365 $460 Not Implemented
AM0280 # 05 Y:1996 05 1996 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $380 $0 Implemented
AM0280 # 06 Y:1996 06 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $320 $100 Implemented
AM0280 # 07 Y:1996 07 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $13,180 $8,000 Implemented
AM0280 # 08 Y:1996 08 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $780 $0 Not Implemented
AS0176 # 01 Y:1996 01 1996 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $6,963 $450 n/a
AS0176 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,024 $8,681 n/a
AS0176 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $1,509 $750 n/a
AS0176 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $258 $510 n/a