Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsSIC | 3053 | Gaskets, Packing And Sealing Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0325 # 13 Y:2005 | 13 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $416 | $276 | Not Implemented |
WV0325 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $16,088 | $12,504 | Not Implemented |
WV0325 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $10,956 | $11,550 | Not Implemented |
WV0325 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,144 | $662 | Implemented |
WV0325 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,050 | $653 | Implemented |
WV0325 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,009 | $0 | Implemented |
WV0325 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,529 | $408 | Not Implemented |
WV0325 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $2,990 | $257 | Implemented |
WV0325 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,637 | $420 | Implemented |
WV0325 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $851 | $426 | Implemented |
WV0325 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $832 | $2,612 | Implemented |
WV0325 # 11 Y:2005 | 11 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $775 | $521 | Not Implemented |
WV0325 # 12 Y:2005 | 12 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $756 | $260 | Implemented |
NC0320 # 05 Y:2005 | 05 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,900 | $1,500 | Not Implemented |
NC0320 # 08 Y:2005 | 08 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $264 | $25 | Implemented |
NC0320 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $902 | $2,000 | Implemented |
NC0320 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $873 | $100 | Implemented |
NC0320 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $193 | $421 | Implemented |
NC0320 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,402 | $50 | Implemented |
NC0320 # 02 Y:2005 | 02 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $9,200 | $100 | Not Implemented |
NC0320 # 01 Y:2005 | 01 | 2005 | INSTALL COMMON HEADER ON COMPRESSORS | $7,563 | $100 | Implemented |
MA0581 # 01 Y:2005 | 01 | 2005 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $165,668 | $1,327,403 | Not Implemented |
MA0581 # 12 Y:2005 | 12 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,134 | $6,429 | Not Implemented |
MA0581 # 11 Y:2005 | 11 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,467 | $8,300 | Implemented |
MA0581 # 10 Y:2005 | 10 | 2005 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $5,166 | $3,100 | Implemented |