IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

554

matching recommendations
Reset
SIC 3061 Mechanical Rubber Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0233 # 04 Y:1999 04 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,355 $0 Not Implemented
IA0233 # 05 Y:1999 05 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,757 $2,000 Implemented
IA0233 # 06 Y:1999 06 1999 ELIMINATE LEAKS IN WATER LINES AND VALVES $314 $60 Not Implemented
SD0234 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,609 $25,688 Not Implemented
SD0234 # 02 Y:1999 02 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $26,750 $21,265 Not Implemented
SD0234 # 03 Y:1999 03 1999 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,768 $13,000 Not Implemented
SD0234 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,069 $1,425 Implemented
SD0234 # 05 Y:1999 05 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,471 $7,825 Not Implemented
SD0234 # 06 Y:1999 06 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,739 $3,334 Not Implemented
SD0234 # 07 Y:1999 07 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $151 $0 Not Implemented
SD0234 # 08 Y:1999 08 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $8,640 $510 Not Implemented
SD0234 # 09 Y:1999 09 1999 INSTALL EQUIPMENT TO MOVE PRODUCT $119,957 $150,000 Not Implemented
MA0438 # 01 Y:1999 01 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,011 $6,075 Not Implemented
MA0438 # 02 Y:1999 02 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,856 $4,925 Not Implemented
MA0438 # 03 Y:1999 03 1999 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,055 $3,400 Not Implemented
MA0436 # 01 Y:1999 01 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $35,895 $41,600 Not Implemented
MA0436 # 02 Y:1999 02 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $24,170 $27,774 Implemented
MA0436 # 03 Y:1999 03 1999 MODERATE COOLING TOWER OUTLET TEMPERATURE $7,745 $12,435 Implemented
MA0436 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $15,831 $44,552 Not Implemented
MA0436 # 05 Y:1999 05 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,698 $75,790 Not Implemented
MA0436 # 06 Y:1999 06 1999 INSTALL OCCUPANCY SENSORS $148 $77 Implemented
MA0436 # 07 Y:1999 07 1999 DISCONNECT BALLASTS $60 $100 Implemented
OK0539 # 01 Y:1998 01 1998 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $33,669 $117,000 Not Implemented
OK0539 # 02 Y:1998 02 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,052 $15,600 Implemented
OK0539 # 03 Y:1998 03 1998 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,678 $5,722 Not Implemented