IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

554

matching recommendations
Reset
SIC 3061 Mechanical Rubber Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AR0091 # 07 Y:1996 07 1996 REPAIR AND ELIMINATE STEAM LEAKS $1,747 $170 Implemented
AR0091 # 08 Y:1996 08 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,839 $1,000 Implemented
AR0091 # 09 Y:1996 09 1996 USE RADIANT HEATER FOR SPOT HEATING $5,749 $2,000 Not Implemented
AR0091 # 10 Y:1996 10 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $152,084 $1,000 Implemented
AR0091 # 11 Y:1996 11 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $39,367 $8,000 Implemented
AR0091 # 12 Y:1996 12 1996 MODIFY MATERIAL APPLICATION METHODS $45,625 $0 Implemented
MO0161 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,126 $2,024 Implemented
MO0161 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $997 $682 Implemented
MO0161 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $122 $0 Implemented
MO0161 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,649 $15,514 Implemented
MO0161 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $180 $0 Implemented
MO0161 # 06 Y:1995 06 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $771 $642 Not Implemented
MO0161 # 07 Y:1995 07 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,440 $306 Implemented
MO0161 # 08 Y:1995 08 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,805 $5,000 Implemented
MO0161 # 09 Y:1995 09 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $18,018 $11,160 Implemented
ND0194 # 01 Y:1994 01 1994 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $32,960 $32,960 Not Implemented
ND0194 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $23,523 $21,380 Implemented
ND0194 # 03 Y:1994 03 1994 OPTIMIZE PLANT POWER FACTOR $21,631 $30,688 Implemented
ND0194 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,480 $900 Not Implemented
ND0194 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,525 $1,050 Not Implemented
ND0194 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,162 $7,693 Implemented
ND0194 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $3,796 $400 Not Implemented
ND0194 # 08 Y:1994 08 1994 REPAIR OR REPLACE STEAM TRAPS $2,707 $2,500 Implemented
ND0194 # 09 Y:1994 09 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,576 $200 Implemented
ND0194 # 10 Y:1994 10 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $403 $500 Not Implemented