Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,537
matching recommendationsSIC | 3069 | Fabricated Rubber Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0447 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,321 | $45,420 | Not Implemented |
MA0447 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $591 | $120 | Implemented |
MA0447 # 06 Y:1999 | 06 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $504 | $455 | Not Implemented |
MA0447 # 07 Y:1999 | 07 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $473 | $748 | Implemented |
MA0447 # 08 Y:1999 | 08 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $940 | $5,925 | Not Implemented |
ND0338 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $278 | $120 | Implemented |
ND0338 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $480 | Implemented |
ND0338 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $1,986 | $1,600 | Not Implemented |
ND0338 # 04 Y:1999 | 04 | 1999 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $318 | $272 | Implemented |
ND0338 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $506 | $800 | Not Implemented |
ND0338 # 06 Y:1999 | 06 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $60 | $87 | Implemented |
ND0338 # 07 Y:1999 | 07 | 1999 | COVER OPEN TANKS | $292 | $400 | Not Implemented |
ND0338 # 08 Y:1999 | 08 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $7,559 | $18,073 | Not Implemented |
ND0333 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,452 | $2,000 | Not Implemented |
ND0333 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $855 | $220 | Implemented |
ND0333 # 03 Y:1999 | 03 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $691 | $1,350 | Not Implemented |
ND0333 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $512 | $300 | Not Implemented |
ND0333 # 05 Y:1999 | 05 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $8,764 | $7,291 | Implemented |
ND0333 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $212 | $480 | Implemented |
ND0333 # 07 Y:1999 | 07 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $12,426 | $15,500 | Implemented |
ND0333 # 08 Y:1999 | 08 | 1999 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,192 | $3,600 | Implemented |
ND0333 # 09 Y:1999 | 09 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $11,110 | $30,000 | Implemented |
ND0333 # 10 Y:1999 | 10 | 1999 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $-669 | $1,264 | Not Implemented |
ND0334 # 01 Y:1999 | 01 | 1999 | APPLY FOR INVESTMENT INCENTIVES | $4,400 | $250 | Implemented |
ND0334 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $358 | $560 | Implemented |