Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
144
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0765 # 03 Y:2016 | 03 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,000 | $1,000 | Implemented |
MA0765 # 06 Y:2016 | 06 | 2016 | REDUCE VENTILATION AIR | $1,080 | $900 | Implemented |
MA0765 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,910 | $95,901 | Not Implemented |
MA0703 # 03 Y:2012 | 03 | 2012 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,287 | $6,060 | Not Implemented |
MA0703 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,359 | $5,625 | Not Implemented |
MA0703 # 01 Y:2012 | 01 | 2012 | OPTIMIZE PLANT POWER FACTOR | $10,588 | $9,425 | Implemented |
MA0703 # 08 Y:2012 | 08 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $803 | $1,200 | Not Implemented |
MA0703 # 06 Y:2012 | 06 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,371 | $2,930 | Not Implemented |
MA0703 # 04 Y:2012 | 04 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,220 | $4,900 | Not Implemented |
MA0703 # 05 Y:2012 | 05 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,040 | $2,080 | Not Implemented |
MA0703 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,254 | $100 | Implemented |
MA0703 # 09 Y:2012 | 09 | 2012 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $332 | $150 | Implemented |
MA0681 # 04 Y:2011 | 04 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $768 | $300 | Not Implemented |
MA0681 # 02 Y:2011 | 02 | 2011 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,294 | $1,220 | Not Implemented |
MA0681 # 05 Y:2011 | 05 | 2011 | INSULATE BARE EQUIPMENT | $152 | $80 | Not Implemented |
MA0681 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $6,162 | $9,261 | Implemented |
MA0681 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,163 | $1,265 | Implemented |
MA0433 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,317 | $3,950 | Implemented |
MA0433 # 04 Y:1999 | 04 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,414 | $0 | Not Implemented |
MA0433 # 05 Y:1999 | 05 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,135 | $0 | Not Implemented |
MA0433 # 06 Y:1999 | 06 | 1999 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $2,000 | $700 | Not Implemented |
MA0433 # 07 Y:1999 | 07 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $6,150 | $1,200 | Not Implemented |
MA0433 # 02 Y:1999 | 02 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,704 | $5,262 | Not Implemented |
MA0433 # 01 Y:1999 | 01 | 1999 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $18,033 | $25,200 | Not Implemented |
MA0387 # 05 Y:1997 | 05 | 1997 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,662 | $21,410 | Not Implemented |