Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
161
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1804 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $459 | $1,500 | n/a |
UK1804 # 05 Y:2018 | 05 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,550 | $2,320 | n/a |
UK1804 # 04 Y:2018 | 04 | 2018 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $195 | $238 | n/a |
UK1804 # 03 Y:2018 | 03 | 2018 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,644 | $147 | n/a |
UK1804 # 01 Y:2018 | 01 | 2018 | INSTALL OCCUPANCY SENSORS | $1,020 | $1,734 | n/a |
UK1504 # 11 Y:2015 | 11 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,705 | $17,000 | Not Implemented |
UK1504 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,473 | $0 | Implemented |
UK1504 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $2,405 | $810 | Implemented |
UK1504 # 08 Y:2015 | 08 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $6,299 | $2,520 | Not Implemented |
UK1504 # 07 Y:2015 | 07 | 2015 | USE ONLY CERTIFIED MOTOR REPAIR SHOPS | $6,448 | $6,381 | Implemented |
UK1504 # 06 Y:2015 | 06 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,819 | $0 | Implemented |
UK1504 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,588 | $1,750 | Implemented |
UK1504 # 04 Y:2015 | 04 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,355 | $2,550 | Not Implemented |
UK1504 # 03 Y:2015 | 03 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $453 | $405 | Implemented |
UK1504 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $5,777 | $34,255 | Not Implemented |
UK1504 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,404 | $93,500 | Not Implemented |
UK1503 # 11 Y:2015 | 11 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $62,362 | $45,000 | Implemented |
UK1503 # 10 Y:2015 | 10 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,034 | $2,460 | Implemented |
UK1503 # 01 Y:2015 | 01 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $605 | $960 | Implemented |
UK1503 # 02 Y:2015 | 02 | 2015 | USE PHOTOCELL CONTROLS | $3,487 | $4,040 | Implemented |
UK1503 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $945 | $520 | Implemented |
UK1503 # 04 Y:2015 | 04 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $5,138 | $3,760 | Implemented |
UK1503 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,831 | $3,000 | Implemented |
UK1503 # 07 Y:2015 | 07 | 2015 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,126 | $1,460 | Implemented |
UK1503 # 09 Y:2015 | 09 | 2015 | INSULATE BARE EQUIPMENT | $17,159 | $9,380 | Implemented |