IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

13,329

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0513 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,800 $700 Implemented
KU0513 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $3,080 $4,830 Implemented
KU0513 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,450 $1,810 Not Implemented
KU0513 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $950 $1,000 Implemented
KU0513 # 06 Y:1999 06 1999 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $1,250 $1,000 Implemented
KU0513 # 07 Y:1999 07 1999 $23,400 $61,400 Implemented
KU0513 # 08 Y:1999 08 1999 $7,210 $2,360 Not Implemented
CO0433 # 01 Y:1999 01 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,630 $1,400 Not Implemented
CO0433 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,250 $600 Not Implemented
CO0433 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $441 $1,208 Not Implemented
CO0433 # 04 Y:1999 04 1999 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $960 $0 Not Implemented
CO0433 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $460 $420 Not Implemented
CO0433 # 06 Y:1999 06 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $340 $0 Not Implemented
CO0433 # 07 Y:1999 07 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $220 $20 Not Implemented
CO0433 # 08 Y:1999 08 1999 $71,760 $60,000 Not Implemented
MS0131 # 01 Y:1999 01 1999 USE PHOTOCELL CONTROLS $601 $814 Not Implemented
MS0131 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $32 $152 Not Implemented
MS0131 # 03 Y:1999 03 1999 INSTALL TIMERS AND/OR THERMOSTATS $146 $236 Implemented
MS0131 # 04 Y:1999 04 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $69 $25 Not Implemented
MS0131 # 05 Y:1999 05 1999 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,970 $0 Implemented
MS0131 # 06 Y:1999 06 1999 BURN WASTE OIL FOR HEAT $1,001 $0 Not Implemented
MS0131 # 07 Y:1999 07 1999 $6,408 $3,978 Implemented
BD0129 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $4,651 $2,500 Not Implemented
BD0129 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,778 $600 Implemented
BD0129 # 03 Y:1999 03 1999 USE POWER DURING OFF-PEAK PERIODS $3,669 $0 Not Implemented