Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,279
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0036 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $287 | $392 | Implemented |
SD0036 # 06 Y:1992 | 06 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $2,507 | $7,150 | Implemented |
SD0036 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $1,480 | $1,520 | Not Implemented |
SD0036 # 08 Y:1992 | 08 | 1992 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,681 | $800 | Not Implemented |
SD0027 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,402 | $1,720 | Implemented |
SD0027 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $3,784 | $206 | Implemented |
SD0027 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $189 | $18 | Not Implemented |
SD0027 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $141 | $0 | Implemented |
SD0027 # 05 Y:1992 | 05 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $2,111 | $2,300 | Not Implemented |
SD0027 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,187 | $700 | Implemented |
SD0027 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $1,039 | $0 | Implemented |
SD0028 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $535 | Implemented |
SD0028 # 02 Y:1992 | 02 | 1992 | INSTALL SET-BACK TIMERS | $846 | $966 | Implemented |
SD0028 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $356 | $966 | Implemented |
SD0028 # 04 Y:1992 | 04 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $745 | $3,200 | Implemented |
SD0028 # 05 Y:1992 | 05 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,745 | $0 | Implemented |
SD0026 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $978 | $1,000 | Implemented |
SD0026 # 02 Y:1992 | 02 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,832 | $200 | Implemented |
SD0026 # 03 Y:1992 | 03 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,982 | $350 | Implemented |
SD0026 # 04 Y:1992 | 04 | 1992 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $4,723 | $499 | Implemented |
SD0026 # 05 Y:1992 | 05 | 1992 | INSULATE BARE EQUIPMENT | $941 | $71 | Implemented |
SD0026 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $178 | $175 | Implemented |
SD0026 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $1,004 | $2,880 | Implemented |
SD0026 # 08 Y:1992 | 08 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,663 | $2,420 | Implemented |
SD0002 # 01 Y:1991 | 01 | 1991 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $4,725 | $3,100 | Implemented |