Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,279
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0447 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,366 | $4,235 | Implemented |
SF0447 # 04 Y:2014 | 04 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $38,158 | $105,000 | Not Implemented |
SF0447 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,962 | $93,924 | Not Implemented |
SF0447 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,341 | $15,131 | Not Implemented |
SF0447 # 08 Y:2014 | 08 | 2014 | USE SOLAR HEAT TO MAKE ELECTRICTY | $139,124 | $745,024 | Not Implemented |
SF0446 # 05 Y:2014 | 05 | 2014 | REPLACE DC EQUIPMENT WITH AC EQUIPMENT | $17,849 | $58,975 | Implemented |
SF0446 # 01 Y:2014 | 01 | 2014 | REPAIR AND ELIMINATE STEAM LEAKS | $3,935 | $840 | Implemented |
SF0446 # 02 Y:2014 | 02 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $477 | $131 | Implemented |
SF0446 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,568 | $5,796 | Implemented |
SF0446 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,787 | $8,897 | Implemented |
SF0446 # 06 Y:2014 | 06 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $56,698 | $210,000 | Not Implemented |
SF0446 # 07 Y:2014 | 07 | 2014 | INSTALL OCCUPANCY SENSORS | $7,640 | $28,695 | Implemented |
SF0446 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,552 | $15,048 | Not Implemented |
SD0478 # 01 Y:2014 | 01 | 2014 | REDUCE SCRAP PRODUCTION | $30,811 | $12,465 | Implemented |
SD0478 # 02 Y:2014 | 02 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,342 | $32,990 | Not Implemented |
SD0478 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,128 | $500 | Implemented |
SD0478 # 04 Y:2014 | 04 | 2014 | INSTALL OCCUPANCY SENSORS | $2,630 | $2,535 | Implemented |
SD0478 # 05 Y:2014 | 05 | 2014 | USE PHOTOCELL CONTROLS | $2,220 | $4,625 | Implemented |
SF0439 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $34,286 | $4,843 | Implemented |
SF0439 # 15 Y:2013 | 15 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,319 | $118,398 | Not Implemented |
SF0439 # 14 Y:2013 | 14 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $370 | $1,980 | Not Implemented |
SF0439 # 13 Y:2013 | 13 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $18,136 | Not Implemented |
SF0439 # 12 Y:2013 | 12 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,184 | $91,986 | Not Implemented |
SF0439 # 11 Y:2013 | 11 | 2013 | INSTALL OCCUPANCY SENSORS | $6,030 | $22,132 | Not Implemented |
SF0439 # 10 Y:2013 | 10 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,646 | $8,690 | Not Implemented |