Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
442
matching recommendationsSIC | 308 | Miscellaneous Plastics Products, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0523 # 02 Y:2002 | 02 | 2002 | OPTIMIZE PLANT POWER FACTOR | $6,907 | $11,770 | Implemented |
MA0523 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,108 | $0 | Implemented |
MA0523 # 04 Y:2002 | 04 | 2002 | $1,510 | $0 | Implemented | |
MA0523 # 05 Y:2002 | 05 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,423 | $2,200 | Not Implemented |
MA0523 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $467 | $250 | Implemented |
MA0523 # 07 Y:2002 | 07 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $359 | $230 | Implemented |
MA0523 # 08 Y:2002 | 08 | 2002 | USE SYNTHETIC LUBRICANT | $308 | $0 | Not Implemented |
AM0421 # 09 Y:2002 | 09 | 2002 | USE PHOTOCELL CONTROLS | $110 | $20 | Implemented |
AM0421 # 08 Y:2002 | 08 | 2002 | USE SYNTHETIC LUBRICANT | $110 | $0 | Not Implemented |
AM0421 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $395 | $180 | Implemented |
AM0421 # 06 Y:2002 | 06 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,550 | $800 | Not Implemented |
AM0421 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $610 | $2,800 | Implemented |
AM0421 # 04 Y:2002 | 04 | 2002 | $690 | $150 | Not Implemented | |
AM0421 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,230 | $500 | Implemented |
AM0421 # 02 Y:2002 | 02 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,040 | $0 | Implemented |
AM0421 # 01 Y:2002 | 01 | 2002 | $9,360 | $7,880 | Implemented | |
OR0415 # 03 Y:2002 | 03 | 2002 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $1,324 | $2,600 | Not Implemented |
OR0415 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $24,100 | $0 | Not Implemented |
OR0415 # 02 Y:2002 | 02 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,686 | $63,600 | Not Implemented |
OR0415 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,036 | $1,800 | Not Implemented |
OR0415 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $1,263 | $4,125 | Not Implemented |
LE0146 # 01 Y:2002 | 01 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,029 | $3,500 | Not Implemented |
LE0146 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $1,559 | $3,000 | Implemented |
LE0146 # 03 Y:2002 | 03 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,443 | $0 | Implemented |
UD0653 # 01 Y:2002 | 01 | 2002 | $1,356,000 | $500,000 | Implemented |