Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

452

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0070 # 05 Y:2004 05 2004 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,990 $130 Implemented
TA0070 # 06 Y:2004 06 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,650 $0 Implemented
TA0070 # 07 Y:2004 07 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $2,088 $0 Not Implemented
TA0070 # 08 Y:2004 08 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,020 $410 Implemented
TA0070 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,885 $50 Implemented
TA0070 # 10 Y:2004 10 2004 DISCONNECT BALLASTS $1,030 $200 Not Implemented
TA0070 # 11 Y:2004 11 2004 INSTALL OCCUPANCY SENSORS $680 $290 Implemented
NC0276 # 01 Y:2004 01 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $13,019 $18,000 Not Implemented
NC0276 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $14,986 $16,406 Not Implemented
NC0276 # 03 Y:2004 03 2004 $18,000 $8,050 Implemented
NC0276 # 04 Y:2004 04 2004 INSULATE BARE EQUIPMENT $14,713 $3,487 Not Implemented
NC0276 # 05 Y:2004 05 2004 DEVELOP A REPAIR/REPLACE POLICY $1,432 $1,085 Implemented
NC0276 # 06 Y:2004 06 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,405 $5,000 Not Implemented
NC0276 # 07 Y:2004 07 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,023 $1,170 Implemented
LL0181 # 01 Y:2004 01 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,934 $395 Implemented
LL0181 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $3,194 $1,013 Implemented
LL0181 # 03 Y:2004 03 2004 INSTALL TIMERS AND/OR THERMOSTATS $2,927 $1,805 Not Implemented
LL0181 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $2,594 $420 Not Implemented
LL0181 # 05 Y:2004 05 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,565 $1,015 Implemented
LL0181 # 06 Y:2004 06 2004 INSTALL OCCUPANCY SENSORS $657 $135 Not Implemented
LL0181 # 07 Y:2004 07 2004 $210 $165 Implemented
LM0065 # 01 Y:2004 01 2004 DISCONNECT BALLASTS $517 $200 Implemented
LM0065 # 02 Y:2004 02 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $713 $110 Implemented
LM0065 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,088 $3,616 Implemented
LM0065 # 04 Y:2004 04 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $241 $118 Implemented