IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

403

matching recommendations
Reset
SIC 308 Miscellaneous Plastics Products, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0132 # 03 Y:2014 03 2014 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,657 $2,600 Not Implemented
DL0132 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,480 $1,375 Implemented
DL0132 # 01 Y:2014 01 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,820 $17,500 Not Implemented
DL0132 # 10 Y:2014 10 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $860 $0 Implemented
DL0132 # 11 Y:2014 11 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $8,380 $0 Implemented
DL0132 # 12 Y:2014 12 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,320 $13,455 Implemented
DL0132 # 13 Y:2014 13 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,030 $14,000 Implemented
IA0527 # 08 Y:2014 08 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $274 $75 Not Implemented
IA0527 # 07 Y:2014 07 2014 INSTALL SPECTRAL REFLECTORS / DELAMP $646 $210 Not Implemented
IA0527 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $577 $1,116 Not Implemented
IA0527 # 01 Y:2014 01 2014 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,002 $11,806 Not Implemented
IA0527 # 02 Y:2014 02 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $10,226 $100 Not Implemented
IA0527 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,843 $365 Implemented
IA0527 # 04 Y:2014 04 2014 USE PHOTOCELL CONTROLS $1,490 $810 Not Implemented
IA0527 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,000 $2,939 Not Implemented
SU0368 # 09 Y:2014 09 2014 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $73,210 $87,750 Not Implemented
SU0368 # 01 Y:2014 01 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $12,372 $0 Not Implemented
SU0368 # 02 Y:2014 02 2014 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $11,558 $0 Not Implemented
SU0368 # 03 Y:2014 03 2014 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $8,530 $0 Not Implemented
SU0368 # 04 Y:2014 04 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,224 $0 Not Implemented
SU0368 # 10 Y:2014 10 2014 ELIMINATE/REDUCE AN OPERATION $4,653 $5,760 Not Implemented
SU0368 # 11 Y:2014 11 2014 INSTALL OCCUPANCY SENSORS $490 $715 Not Implemented
SU0368 # 05 Y:2014 05 2014 DISCONNECT BALLASTS $818 $0 Not Implemented
SU0368 # 06 Y:2014 06 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,361 $5,132 Not Implemented
SU0368 # 08 Y:2014 08 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,026 $2,021 Not Implemented