Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsSIC | 3081 | Unsupported Plastics Film & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0482 # 01 Y:2014 | 01 | 2014 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $177,357 | $198,000 | Not Implemented |
WV0482 # 16 Y:2014 | 16 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $507 | $1,167 | Implemented |
WV0482 # 15 Y:2014 | 15 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,123 | $5,400 | Not Implemented |
WV0482 # 14 Y:2014 | 14 | 2014 | DEVELOP A REPAIR/REPLACE POLICY | $3,427 | $708 | Implemented |
WV0482 # 13 Y:2014 | 13 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,804 | $200 | Implemented |
WV0482 # 12 Y:2014 | 12 | 2014 | INSTALL OCCUPANCY SENSORS | $6,231 | $1,020 | Not Implemented |
WV0482 # 11 Y:2014 | 11 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,903 | $1,632 | Implemented |
WV0482 # 10 Y:2014 | 10 | 2014 | REDUCE EXCESSIVE BOILER BLOWDOWN | $7,886 | $8,000 | Not Implemented |
WV0482 # 09 Y:2014 | 09 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,132 | $27,380 | Not Implemented |
WV0482 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,536 | $9,000 | Implemented |
WV0482 # 07 Y:2014 | 07 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $17,822 | $26,000 | Implemented |
WV0482 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,791 | $38,441 | Implemented |
WV0482 # 05 Y:2014 | 05 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $35,144 | $1,000 | Implemented |
WV0482 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,141 | $51,865 | Implemented |
WV0482 # 03 Y:2014 | 03 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $37,833 | $0 | Not Implemented |
WV0482 # 02 Y:2014 | 02 | 2014 | REPAIR OR REPLACE STEAM TRAPS | $135,791 | $7,100 | Implemented |
NC0316 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $327 | $100 | Implemented |
NC0316 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $491 | $321 | Not Implemented |
NC0316 # 02 Y:2005 | 02 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $10,570 | $26,949 | Not Implemented |
NC0316 # 01 Y:2005 | 01 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $18,271 | $87,125 | Not Implemented |
NC0306 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $96,975 | $360,700 | Not Implemented |
NC0306 # 07 Y:2004 | 07 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,785 | $100 | Implemented |
NC0306 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $204 | $79 | Not Implemented |
NC0306 # 05 Y:2004 | 05 | 2004 | OPERATE BOILERS ON HIGH FIRE SETTING | $6,289 | $2,100 | Not Implemented |
NC0306 # 04 Y:2004 | 04 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,305 | $5,000 | Implemented |