Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
221
matching recommendationsSIC | 3082 | Unsupported Plastics Profile Shapes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0362 # 10 Y:2009 | 10 | 2009 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,248 | $520 | Implemented |
BD0362 # 09 Y:2009 | 09 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $15,684 | $2,000 | Not Implemented |
BD0362 # 08 Y:2009 | 08 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $200 | $0 | Not Implemented |
BD0362 # 07 Y:2009 | 07 | 2009 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $7,156 | $60,000 | Not Implemented |
BD0362 # 06 Y:2009 | 06 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,913 | $3,300 | Implemented |
BD0362 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,945 | $2,900 | Implemented |
BD0362 # 04 Y:2009 | 04 | 2009 | USE SYNTHETIC LUBRICANT | $1,202 | $300 | Implemented |
BD0362 # 03 Y:2009 | 03 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $701 | $100 | Implemented |
BD0362 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,931 | $36,000 | Implemented |
WV0317 # 13 Y:2005 | 13 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $400 | $240 | Implemented |
WV0317 # 01 Y:2005 | 01 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $28,323 | $0 | Not Implemented |
WV0317 # 02 Y:2005 | 02 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $23,795 | $50,000 | Not Implemented |
WV0317 # 08 Y:2005 | 08 | 2005 | INSULATE BARE EQUIPMENT | $4,285 | $128 | Implemented |
WV0317 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,415 | $5,677 | Not Implemented |
WV0317 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,041 | $60 | Implemented |
WV0317 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,531 | $680 | Implemented |
WV0317 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $4,392 | $855 | Implemented |
WV0317 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $761 | $205 | Implemented |
WV0317 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,217 | $490 | Implemented |
WV0317 # 09 Y:2005 | 09 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,086 | $2,295 | Implemented |
WV0317 # 10 Y:2005 | 10 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,435 | $2,075 | Not Implemented |
WV0317 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $1,219 | $2,680 | Implemented |
WV0309 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,239 | $8,590 | Implemented |
WV0309 # 02 Y:2005 | 02 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,338 | $550 | Implemented |
WV0309 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $9,618 | $1,147 | Implemented |