Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 3083 | Laminated Plastics Plate & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0176 # 05 Y:1997 | 05 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $16,243 | $15,295 | Implemented |
SD0176 # 04 Y:1997 | 04 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $6,499 | $22,356 | Implemented |
SD0176 # 06 Y:1997 | 06 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $14,812 | $0 | Implemented |
SD0176 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $878 | $500 | Implemented |
SD0176 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,636 | $1,250 | Implemented |
SD0176 # 07 Y:1997 | 07 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $133,998 | $30,000 | Implemented |
SD0176 # 01 Y:1997 | 01 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,704 | $0 | Implemented |
SD0176 # 08 Y:1997 | 08 | 1997 | INSTALL SYSTEM TO COLLECT SCRAP | $618,145 | $200,000 | Not Implemented |
SD0156 # 03 Y:1996 | 03 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $1,278 | $100 | Implemented |
SD0156 # 01 Y:1996 | 01 | 1996 | COVER OPEN TANKS | $3,289 | $521 | Implemented |
SD0156 # 02 Y:1996 | 02 | 1996 | INSULATE BARE EQUIPMENT | $3,632 | $651 | Implemented |
SD0156 # 09 Y:1996 | 09 | 1996 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $800 | $418 | Implemented |
SD0156 # 04 Y:1996 | 04 | 1996 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $2,794 | $875 | Implemented |
SD0156 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,515 | $22,017 | Implemented |
SD0156 # 06 Y:1996 | 06 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $13,620 | $12,370 | Implemented |
SD0156 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $4,356 | $3,822 | Implemented |
SD0156 # 08 Y:1996 | 08 | 1996 | USE LESS WASTEFUL PACKAGING | $360 | $400 | Implemented |
SD0165 # 11 Y:1997 | 11 | 1997 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $2,250 | $1,100 | Implemented |
SD0165 # 13 Y:1997 | 13 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $296,400 | $20,000 | Implemented |
SD0165 # 02 Y:1997 | 02 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,369 | $0 | Implemented |
SD0165 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,422 | $650 | Implemented |
SD0165 # 08 Y:1997 | 08 | 1997 | INSTALL OCCUPANCY SENSORS | $3,812 | $1,476 | Implemented |
SD0165 # 05 Y:1997 | 05 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $2,716 | $900 | Implemented |
SD0165 # 07 Y:1997 | 07 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,369 | $4,110 | Implemented |
SD0165 # 09 Y:1997 | 09 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $50,000 | $0 | Implemented |