Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 3083 | Laminated Plastics Plate & Sheet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0055 # 07 Y:2010 | 07 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $0 | $0 | Implemented |
MZ0055 # 06 Y:2010 | 06 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $0 | $0 | Implemented |
MZ0055 # 05 Y:2010 | 05 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,888 | $0 | Not Implemented |
MZ0055 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,282 | $16,460 | Implemented |
MZ0055 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,900 | $1,160 | Implemented |
MZ0055 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $770 | $700 | Not Implemented |
MZ0055 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,916 | $1,100 | Implemented |
LE0301 # 02 Y:2010 | 02 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $185,253 | $118,000 | Not Implemented |
LE0301 # 16 Y:2010 | 16 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $153 | $1,000 | Implemented |
LE0301 # 15 Y:2010 | 15 | 2010 | INSTALL OCCUPANCY SENSORS | $1,097 | $2,035 | Implemented |
LE0301 # 14 Y:2010 | 14 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,029 | $20,000 | Implemented |
LE0301 # 13 Y:2010 | 13 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,550 | $2,440 | Implemented |
LE0301 # 11 Y:2010 | 11 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,938 | $3,000 | Not Implemented |
LE0301 # 12 Y:2010 | 12 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,001 | $4,500 | Implemented |
LE0301 # 01 Y:2010 | 01 | 2010 | REPLACE BOILER | $284,580 | $500,000 | Not Implemented |
LE0301 # 03 Y:2010 | 03 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $57,617 | $13,469 | Implemented |
LE0301 # 04 Y:2010 | 04 | 2010 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $28,496 | $10,000 | Not Implemented |
LE0301 # 05 Y:2010 | 05 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $24,299 | $75,000 | Not Implemented |
LE0301 # 06 Y:2010 | 06 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $23,321 | $4,200 | Implemented |
LE0301 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,721 | $22,000 | Not Implemented |
LE0301 # 08 Y:2010 | 08 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $11,375 | $100,000 | Not Implemented |
LE0301 # 09 Y:2010 | 09 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $8,386 | $8,000 | Not Implemented |
LE0301 # 10 Y:2010 | 10 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,358 | $870 | Implemented |
UD0820 # 14 Y:2010 | 14 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $4,962 | $4,550 | Implemented |
UD0820 # 13 Y:2010 | 13 | 2010 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $7,994 | $45,000 | Not Implemented |