Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
703
matching recommendationsSIC | 3084 | Plastics Pipe |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0067 # 09 Y:1993 | 09 | 1993 | INSTALL SET-BACK TIMERS | $596 | $720 | Implemented |
SD0067 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43 | $0 | Implemented |
SD0067 # 11 Y:1993 | 11 | 1993 | INSTALL SET-BACK TIMERS | $391 | $100 | Implemented |
SD0067 # 12 Y:1993 | 12 | 1993 | USE PHOTOCELL CONTROLS | $219 | $115 | Implemented |
SD0067 # 13 Y:1993 | 13 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $40 | $20 | Not Implemented |
OR0191 # 01 Y:1993 | 01 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,984 | $400 | Implemented |
OR0191 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $438 | $567 | Implemented |
OR0191 # 03 Y:1993 | 03 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,156 | $7,425 | Not Implemented |
OR0191 # 04 Y:1993 | 04 | 1993 | OPTIMIZE PLANT POWER FACTOR | $5,843 | $12,300 | Not Implemented |
OR0191 # 05 Y:1993 | 05 | 1993 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $36,422 | $41,000 | Implemented |
OR0191 # 06 Y:1993 | 06 | 1993 | INSULATE BARE EQUIPMENT | $8,272 | $13,663 | Implemented |
OR0175 # 01 Y:1993 | 01 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,571 | $0 | Implemented |
OR0175 # 02 Y:1993 | 02 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $942 | $390 | Not Implemented |
OR0175 # 03 Y:1993 | 03 | 1993 | USE PHOTOCELL CONTROLS | $192 | $132 | Implemented |
OR0175 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $246 | $929 | Implemented |
UF0020 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,439 | $5,421 | Not Implemented |
UF0020 # 02 Y:1992 | 02 | 1992 | INSTALL SPECTRAL REFLECTORS / DELAMP | $28,591 | $9,720 | Not Implemented |
UF0020 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $94 | $643 | Not Implemented |
UF0020 # 04 Y:1992 | 04 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,160 | $1,320 | Implemented |
UF0020 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,332 | $16,490 | Implemented |
UF0004 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,045 | $4,157 | Implemented |
UF0004 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $550 | $1,831 | Implemented |
UF0004 # 03 Y:1991 | 03 | 1991 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,864 | $1,500 | Implemented |
UF0004 # 04 Y:1991 | 04 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,887 | $0 | Implemented |
UF0004 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,153 | $11,146 | Implemented |